IDE interface Test Passed, Configuration/Setup error
UPC - 087944520719
View all IBM 847671U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 186 highlights
Diagnostic Error Code 020-195-XXX PCI Test aborted by user 020-196-XXX PCI test halt, error threshold exceeded 020-197-XXX PCI test warning 020-198-XXX PCI test aborted 020-199-XXX PCI test failed, cause unknown 020-262-XXX PCI system error 025-000-XXX IDE interface Test Passed 025-00X-XXX 025-01X-XXX IDE interface failure 025-027-XXX IDE interface Configuration/Setup error 025-02X-XXX 025-03X-XXX 025-04X-XXX IDE Interface failure 025-195-XXX IDE interface Test aborted by user FRU/Action 1. Information 2. Re-start the test, if need to 1. Press F3 to review the log file. See "Viewing the test log" on page 14. 2. Re-start the test to reset the log file. 1. Make sure component that is called out is enabled and/or connected 2. Re-run test 3. Component that is called out in warning statement 4. Component under test 1. If a component is called out, make sure it is enabled and/or connected 2. Flash the system and re-test 3. Go to "Undetermined problems" on page 198 1. Go to "Undetermined problems" on page 198. 2. Flash the system and re-test 3. Replace component under function test. 1. PCI card 2. Riser card, if installed 3. System board 1. No action 1. IDE signal cable 2. Check power supply 3. IDE device 4. System board 1. IDE signal cable 2. Flash the system 3. IDE device 4. System board 1. IDE signal cable 2. Check power supply 3. IDE device 4. System board 1. Information 2. Re-start the test, if need to 178 Netfinity Server HMM