Diagnostic Error Code 170-000-XXX Voltage Sensor(s) Test Passed 170-0XX-XXX Voltage Sensor(s) failure 170-195-XXX Voltage Sensor(s) Test aborted by user 170-196-XXX Voltage Sensor(s) test halt, error threshold exceeded 170-197-XXX Voltage Sensor(s) test warning 170-198-XXX Voltage Sensor(s) test aborted 170-199-XXX Voltage Sensor(s) test failed, cause unknown 170-250-XXX 170-251-XXX Voltage Sensor(s) Voltage limit error 170-254-XXX Voltage Sensor(s) Voltage Regulator Module error 175-000-XXX Thermal Sensor(s) Test Passed 175-0XX-XXX Thermal Sensor(s) failure FRU/Action 1. No action 1. Flash system 2. System board 1. Information 2. Re-start the test, if need to 1. Press F3 to review the log file. See "Viewing the test log" on page 14. 2. Re-start the test to reset the log file. 1. Make sure component that is called out is enabled and/or connected 2. Re-run test 3. Component that is called out in warning statement 4. Component under test 1. If a component is called out, make sure it is enabled and/or connected 2. Flash the system and re-test 3. Go to "Undetermined problems" on page 198 1. Go to "Undetermined problems" on page 198. 2. Flash the system and re-test 3. Replace component under function test. 1. Power supply 2. System board 1. Voltage Regulator Module (VRM) 2. Microprocessor 3. System board 1. No action 1. Flash system 2. System board IBM Netfinity 3000 - Type 8476 185