IBM 86601RU Hardware Maintenance Manual - Page 276
PCI Card for the PCI, J1, J2, J3, or J4.
![]() |
UPC - 087944414230
View all IBM 86601RU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 276 highlights
Diagnostic Panel LED DASD 1 LED on (The LED located next to the drive bay that the failing drive is installed in will be turned on.) FAN 1 LED on FAN 2 LED on FAN 3 LED on MEM LED on (The LED next to the failing DIMM is on.) NMI LED on (Machine check error) PCI 1 LED on PCI 2 LED on PS1 LED on PS2 LED on SMI LED on FRU/Action 1. Failing drive. 2. Be sure the fans are operating correctly and the air flow is good. 3. SCSI Backplane 1. Fan 1 2. Fan Cable 3. System Board 1. Fan 2 2. Fan Cable 3. System Board 1. Fan 3 2. Fan Cable 3. System Board 1. Failing DIMM in slot J1, J2, J3, or J4). 2. Processor Board 3. System Board 1. Reboot the system. 2. Check the system Board LED(s); if on, see "System board LEDs" on page 290. 3. Check the system error log. 1. PCI Card for the PCI slot LED that is turned on 2. System Board 3. Processor Board 1. Card in slot 1 or 4 2. System Board 3. Processor Board 1. Check the DC Good LED on power supply 1. If off, replace power supply 1. 2. Power Backplane 1. Check the DC Good LED on power supply 2. If off, replace power supply 2. 2. Power Backplane 1. Reboot the system. 2. Check the system Board LED(s); if on, see "System board LEDs" on page 290. 268 Netfinity Server HMM
![](/manual_guide/products/ibm-866011u-hardware-maintenance-manual-12f5559/276.png)