IBM 867282X Maintenance Manual - Page 34

Error code, Description, Explanation, Action, Start, Control Panel, Networks, Adapters, Properties

Page 34 highlights

Table 4. NDIS (Windows NT or Windows 2000) driver messages for the Ethernet controller (continued) Error code (hex) Description 0x03 Explanation: Failed self-test. Action: Make sure a cable is attached to the Ethernet connector. 0x0D Explanation: Could not allocate enough memory for transmit queues. Action: 1. From the Windows NT desktop, select Start → Control Panel → Networks → Adapters. 2. Select your IBM Ethernet adapter from the list. 3. Select Properties → Advanced. 4. Lower the resource values that apply to the transmit queue. 0x0E Explanation: Could not allocate enough memory for receive queue. Action: 1. From the Windows NT desktop, select Start →Control Panel →Networks →Adapters. 2. Select your IBM Ethernet adapter from the list. 3. Select Properties →Advanced. 4. Lower the resource values that apply to the receive queue. 0x0F Explanation: Could not allocate enough memory for other structures. Action: 1. From the Windows NT desktop, select Start → Control Panel → Networks → Adapters. 2. Select your IBM Ethernet adapter from the list. 3. Select Properties →Advanced. 4. Lower the value for the resource named in the message. 0x10 Explanation: Did not find any Ethernet controllers. Action: Using the Configuration/Setup Utility program, make sure that Ethernet is enabled. 0x11 Explanation: Multiple Ethernet controllers found, but none matched the required ID. Action: Using the Configuration/Setup Utility program, make sure that Ethernet is enabled. 0x13 Explanation: Did not find any Ethernet controllers that matched the required subven/subdev. Action: Using the Configuration/Setup Utility program, make sure that Ethernet is enabled. 0x16 Explanation: Single adapter found, but multiple instances tried to load. Action: Using the Configuration/Setup Utility program, make sure that Ethernet is enabled, and that the slot containing the IBM xSeries 200 10/100 Ethernet Adapter or the IBM 10/100 Etherjet PCI adapter is enabled. 0x17 Explanation: Slot parameter not specified in the registry. Action: Remove the adapter driver and reinstall it. 26 Hardware Maintenance Manual: xSeries 300

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120

Table 4. NDIS (Windows NT or Windows 2000) driver messages for the Ethernet
controller (continued)
Error code
(hex)
Description
0x03
Explanation:
Failed self-test.
Action:
Make sure a cable is attached to the
Ethernet connector.
0x0D
Explanation:
Could not allocate enough memory for transmit queues.
Action:
1.
From the Windows NT desktop, select
Start
Control Panel
Networks
Adapters
.
2.
Select your IBM Ethernet adapter from the list.
3.
Select
Properties
Advanced
.
4.
Lower the resource values that apply to the transmit queue.
0x0E
Explanation:
Could not allocate enough memory for receive queue.
Action:
1.
From the Windows NT desktop, selec
t Start
Control Panel
Networks
Adapter
s.
2.
Select your IBM Ethernet adapter from the list.
3.
Select
Properties
Advanced
.
4.
Lower the resource values that apply to the receive queue.
0x0F
Explanation:
Could not allocate enough memory for other structures.
Action:
1.
From the Windows NT desktop, select
Start
Control Panel
Networks
Adapters
.
2.
Select your IBM Ethernet adapter from the list.
3.
Select
Properties
Advanced
.
4.
Lower the value for the resource named in the message.
0x10
Explanation:
Did not find any Ethernet controllers.
Action:
Using the
Configuration/Setup Utility program, make sure that Ethernet is enabled.
0x11
Explanation:
Multiple Ethernet controllers found, but none matched the
required ID.
Action:
Using the Configuration/Setup Utility program, make
sure that Ethernet is enabled.
0x13
Explanation:
Did not find any Ethernet controllers that matched the
required subven/subdev.
Action:
Using the Configuration/Setup Utility
program, make sure that Ethernet is enabled.
0x16
Explanation:
Single adapter found, but multiple instances tried to load.
Action:
Using the Configuration/Setup Utility program, make sure that
Ethernet is enabled, and that the slot containing the IBM xSeries 200
10/100 Ethernet Adapter or the IBM 10/100 Etherjet PCI adapter is
enabled.
0x17
Explanation:
Slot parameter not specified in the registry.
Action:
Remove
the adapter driver and reinstall it.
26
Hardware Maintenance Manual: xSeries 300