IBM 8685 Hardware Maintenance Manual - Page 146
System Management: Failed
UPC - 087944957171
View all IBM 8685 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 146 highlights
Note: See "System" on page 162 to determine which components should be replaced by a field service technician. Error code/symptom FRU/action 035-xxx-S99 (Failed RAID test on PCI slot S. S = number of failing PCI slot. Check System Error Log before replacing a FRU.) 1. Adapter 2. SCSI backplane 3. Cable 035-xxx-snn (Check System Error Log before replacing a FRU. s = number of v Hard disk drive with SCSI ID nn on RAID adapter in PCI slot s. failing PCI slot, nn = SCSI ID of failing fixed disk.) 035-253-S99 (RAID adapter initialization failure) 1. ServeRAID adapter in slot s is not configured properly. Obtain the basic and extended configuration status and see the ServeRAID Hardware Maintenance Manual for more information. 2. Cable. 3. SCSI backplane. 4. Adapter. 075-xxx-000 (Failed power supply test) v Power supply 089-xxx-001 (Failed microprocessor test) 1. VRM 1 for microprocessor 1 2. Microprocessor 1 089-xxx-002 (Failed optional microprocessor test) 1. VRM 2 for optional microprocessor 2 2. Optional microprocessor 2 089-xxx-003 (Failed optional microprocessor test) 1. VRM 3 for optional microprocessor 3 2. Optional microprocessor 3 089-xxx-004 (Failed optional microprocessor test) 1. VRM 4 for optional microprocessor 4 2. Optional microprocessor 4 166-198-000 System Management: Aborted (Unable to communicate with ASM. It may be busy. Run the test again.) 1. Run the diagnostic test again. 2. Correct other error conditions and retry. These include other failed system management tests and items logged in the System Error Log of the optional Remote Supervisor Adapter. 3. Disconnect all server and option power cords from the server, wait 30 seconds, reconnect, and retry. 4. Remote Supervisor Adapter, if installed. 5. System board. 166-201-001 System Management: Failed 1. If installed, reseat the I2C cable between the Remote (I2C bus error(s) See SERVPROC and Supervisor Adapter (in PCI slot 1/J26) and the system board DIAGS entries in event log.) (J16). 2. Reseat memory DIMMs. 3. Memory DIMMs. 4. Memory card. 5. System board. 166-201-002 System Management: Failed 1. Reseat I2C cable between the diagnostics panel and the (I2C bus error(s) See SERVPROC and system board (J46). DIAGS entries in event log.) 2. Diagnostics panel. 3. System board. 136 xSeries 255 Type 8685: Hardware Maintenance Manual and Troubleshooting Guide