IBM 8685 Hardware Maintenance Manual - Page 73

Working with the optional xSeries 6-Pack Hot-Swap Hard Drive Expansion Kit, are known

Page 73 highlights

Cable-management arm bracket Cable-management arm Captive screw Tab Fan bay 7 (fan removed) 1) Remove the fan from fan bay 7. 2) Insert the tab on the cable-management-arm bracket into the corresponding slot on the server. 3) Tighten the captive screw on the cable-management-arm bracket to the server. 4) Reinstall the fan in fan bay 7. 17. If you have other options to install or remove, do so now; otherwise, go to "Completing the installation" on page 106. Working with the optional xSeries 6-Pack Hot-Swap Hard Drive Expansion Kit Your server contains hardware that enables you to replace a failed hard disk drive without turning off the server. Therefore, you have the advantage of continuing to operate your system while a hard disk drive is removed or installed. These drives are known as hot-swap drives. The hot-swap drives are attached to a hot-swap hard disk drive backplane. The backplane is a printed circuit board behind the drive bays. For more information about drive bays and drive installation, see "Installing internal drives" on page 73. The low voltage differential (LVD) SCSI hot-swap hard disk drive backplane supports a maximum of six slim-high, hot-swap hard disk drives. Chapter 4. Customer replaceable units 63

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220

Tab
Fan bay 7
(fan removed)
Captive
screw
Cable-management
arm
Cable-management
arm bracket
1)
Remove the fan from fan bay 7.
2)
Insert the tab on the cable-management-arm bracket into the
corresponding slot on the server.
3)
Tighten the captive screw on the cable-management-arm bracket to the
server.
4)
Reinstall the fan in fan bay 7.
17.
If you have other options to install or remove, do so now; otherwise, go to
“Completing the installation” on page 106.
Working with the optional xSeries 6-Pack Hot-Swap Hard Drive
Expansion Kit
Your server contains hardware that enables you to replace a failed hard disk drive
without turning off the server. Therefore, you have the advantage of continuing to
operate your system while a hard disk drive is removed or installed. These drives
are known as
hot-swap
drives. The hot-swap drives are attached to a hot-swap
hard disk drive
backplane
. The backplane is a printed circuit board behind the drive
bays. For more information about drive bays and drive installation, see “Installing
internal drives” on page 73. The low voltage differential (LVD) SCSI hot-swap hard
disk drive backplane supports a maximum of six slim-high, hot-swap hard disk
drives.
Chapter 4. Customer replaceable units
63