IBM 8685 Hardware Maintenance Manual - Page 160
Remote Supervisor Adapter, if installed, Disconnect all server and option power cords from server
UPC - 087944957171
View all IBM 8685 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 160 highlights
Note: See "System" on page 162 to determine which components should be replaced by a field service technician. Error code/symptom FRU/action 1304 (I2C cable to diagnostic LED board not found) 1. Power switch assembly 2. System board 1601 (The system is able to communicate to the system management processor, but the system management processor failed to respond at the start of POST.) Do the following before replacing a FRU: 1. Remove the ac power to the server, wait 20 seconds; then, reconnect the ac power. Wait 30 seconds; then, turn on the server. 2. Flash update the system management processor. 1. Remote Supervisor Adapter, if installed 2. System board 1602 (Cable for optional service processor v Disconnect all server and option power cords from server, wait adapter not installed) 30 seconds, reconnect, and retry. 1762 (Hard disk configuration error) 1. Hard disk drive. 2. Hard disk cables. 3. Run the Configuration/Setup Utility program. 4. Hard disk adapter. 5. SCSI backplane. 6. System board. 178X (Fixed disk error) 1. Hard disk cables. 2. Run diagnostics. 3. Hard disk adapter. 4. Hard disk drive. 5. System board. 1800 (No more hardware interrupt available for PCI adapter) 1. Run the Configuration/Setup Utility program. 2. Failing adapter. 3. System board. 1962 (Drive does not contain a valid boot sector) 1. Verify that a startable operating system is installed. 2. Run diagnostics. 3. Hard disk drive. 4. SCSI backplane. 5. Cable. 6. System board. 2400 (Video controller test failure) 1. Video adapter (if installed) 2. System board 2462 (Video memory configuration error) 1. Video adapter (if installed) 2. System board 150 xSeries 255 Type 8685: Hardware Maintenance Manual and Troubleshooting Guide