IBM DTLA-305040 Hard Drive Specifications - Page 134
Idle E3h/97h
![]() |
View all IBM DTLA-305040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 134 highlights
12.7 Idle (E3h/97h) Command Block Output Registers Register 7 6 5 4 3 2 1 0 Data Feature Sector Count V V V V V V V V Sector Number Cylinder Low Cylinder High Device/Head 1 - 1 D - - - - Command 1 1 1 0 0 0 1 1 Command Block Input Registers Register 7 6 5 4 3 2 1 0 Data Error see below Sector Count Sector Number Cylinder Low Cylinder High Device/Head Status see below Error Register 76543210 CRC UNC 0 IDN 0 ABT T0N AMN 00000V00 Status Register 7 6 5 4 3 2 10 BSY RDY DF DSC DRQ COR IDX ERR 0 V 0 V - 0 -V Figure 93. Idle Command (E3h/97h) The Idle command causes the device to enter Idle mode immediately and to set the auto power down time-out parameter (standby timer). And the timer then starts counting down. When the Idle mode is entered, the device is spun up to operating speed. If the device is already spinning, the spin up sequence is not executed. During Idle mode the device is spinning and ready to respond to host commands immediately. Output parameters to the device Sector Count Time-out Parameter. If it is zero, the automatic power down sequence is disabled. If it is non-zero, the automatic power down sequence is enabled. The time-out interval is shown below: Value ------- 0 1-240 241-251 252 253 254 255 Time-out Timer disabled Value * 5 seconds (Value-240) * 30 minutes 21 minutes 8 hours 21 minutes 10 seconds 21 minutes 15 seconds Deskstar 40GV & 75GXP hard disk drive specifications 122
![](/manual_guide/products/ibm-dtla307075-hard-drive-specifications-d371d8a/134.png)