IBM DTLA-305040 Hard Drive Specifications - Page 166
Set Features EFh
![]() |
View all IBM DTLA-305040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 166 highlights
12.28 Set Features (EFh) Command Block Output Registers Register 7 6 5 4 3 2 1 0 Data Feature V V V V V V V V Sector Count Note 1 Sector Number Cylinder Low Cylinder High Device/Head 1 - 1 D - - - - Command 1 1 1 0 1 1 1 1 Command Block Input Registers Register 7 6 5 4 3 2 1 0 Data Error see below Sector Count Sector Number Cylinder Low Cylinder High Device/Head Status see below Error Register 76543210 CRC UNC 0 IDN 0 ABT T0N AMN 00000V00 Status Register 7 6 5 4 3 2 10 BSY RDY DF DSC DRQ COR IDX ERR 0 V 0 - - 0 -V Figure 118. Set Features Command (EFh) The Set Feature command is to establish the following parameters which affect the execution of certain features as shown in below table. ABT will be set to 1 in the Error Register if the Feature register contains any undefined values. Output parameters to the device Feature Destination code for this command. 02H Enable write cache 03H Set transfer mode based on value in sector count register 05H Enable Advanced Power Management 06H Enable Power-up in Standby feature set 07H Power-up in Standby feature set device spin-up 09H Enable Address Offset mode 42H Enable Automatic Acoustic Management 44H 40 bytes of ECC apply on Read Long/Write Long commands 55H Disable read look-ahead feature Deskstar 40GV & 75GXP hard disk drive specifications 154
![](/manual_guide/products/ibm-dtla307075-hard-drive-specifications-d371d8a/166.png)