IBM DTLA-305040 Hard Drive Specifications - Page 192
Output Parameters To The Drive, Sector Count
![]() |
View all IBM DTLA-305040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 192 highlights
Output Parameters To The Drive Sector Count Time-out Parameter. If it is 0, the automatic power down sequence is disabled. If it is nonzero, the automatic power down sequence is enabled. The time-out interval is shown below: Value -------- 0 1-240 241-251 252 253 254 255 Time-out Timer disabled Value * 5 seconds Value-240) * 30 minutes 21 minutes 8 hours 21 minutes 10 seconds 21 minutes 15 seconds When the automatic power down sequence is enabled, the drive will enter Standby mode automatically if the time-out interval expires with no drive access from the host. The time-out interval will be reinitialized if there is a drive access before the time-out interval expires. Deskstar 40GV & 75GXP hard disk drive specifications 180
![](/manual_guide/products/ibm-dtla307075-hard-drive-specifications-d371d8a/192.png)
Output Parameters To The Drive
Sector Count
Time-out Parameter. If it is 0, the automatic power down sequence is disabled. If
it is nonzero, the automatic power down sequence is enabled.
The time-out
interval is shown below:
21 minutes 15 seconds
255
21 minutes 10 seconds
254
8 hours
253
21 minutes
252
Value-240) * 30 minutes
241-251
Value * 5 seconds
1-240
Timer disabled
0
---------------------
--------
Time-out
Value
When the automatic power down sequence is enabled, the drive will enter
Standby mode automatically if the time-out interval expires with no drive access
from the host. The time-out interval will be reinitialized if there is a drive access
before the time-out interval expires.
Deskstar 40GV & 75GXP hard disk drive specifications