Icom IC-7000 Instruction Manual - Page 145

CI-V Baud Rate, CI-V Address, CI-V Transceive, REF Adjust, Front Keypad Type

Page 145 highlights

■ Miscellaneous (others) Set mode (continued) 47 Front Keypad Type This item selects the keypad type that connected to the [MIC] connector. Dot/Dash Dot/Dash (default) 48 CI-V Baud Rate This item sets the data transfer rate. 300, 1200, 4800, 9600, 19200 bps and "Auto" are available. When "Auto" is selected, the baud rate is automatically set according to the connected controller or remote controller. Auto Auto baud rate (default) 49 CI-V Address To distinguish equipment, each CI-V transceiver has its own Icom standard address in hexadecimal code. The IC-7000's address is 70h. When 2 or more IC-7000's are connected to an optional CT-17 ci-v level converter, rotate [DIAL] to select a different address for each IC-7000 in the range 01h to 7Fh. 70h Address of 70h (default) 50 CI-V Transceive Transceive operation is possible with the IC-7000 connected to other Icom HF transceivers or receivers. When "ON" is selected, changing the frequency, operating mode, etc. on the IC-7000 automatically changes those of connected transceivers (or receivers) and vice versa. ON Transceive ON (default) 51 REF Adjust This item adjusts the internal reference frequency within 0 to 100% range in 1 % steps. SET MODE 13 Ext Keypad External keypad 19200 19200 bps 7Fh Address of 7Fh OFF Transceive OFF 13 136

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

136
13
SET MODE
13
Miscellaneous (others) Set mode
(continued)
48
CI-V Baud Rate
This item sets the data transfer rate. 300, 1200,
4800, 9600, 19200 bps and “Auto” are available.
When “Auto” is selected, the baud rate is automati-
cally set according to the connected controller or
remote controller.
Auto
Auto baud rate
(default)
19200
19200 bps
49
CI-V Address
To distinguish equipment, each CI-V transceiver has
its own Icom standard address in hexadecimal code.
The IC-7000’s address is 70h.
When 2 or more IC-7000’s are connected to an op-
tional CT-17
CI
-
V
LEVEL
CONVERTER
, rotate
[DIAL]
to select a different address for each IC-7000 in the
range 01h to 7Fh.
70h
Address of 70h
(default)
7Fh
Address of 7Fh
50
CI-V Transceive
Transceive operation is possible with the IC-7000
connected to other Icom HF transceivers or receivers.
When “ON” is selected, changing the frequency,
operating mode, etc. on the IC-7000 automatically
changes those of connected transceivers (or receiv-
ers) and vice versa.
ON
Transceive ON
(default)
OFF
Transceive OFF
51
REF Adjust
This item adjusts the internal reference frequency
within 0 to 100% range in 1 % steps.
47
Front Keypad Type
This item selects the keypad type that connected to
the
[MIC]
connector.
Dot/Dash
Dot/Dash (default)
Ext Keypad
External keypad