Intel SR1530HCLS Product Specification - Page 22
Cooling Sub-System, Fan Module Assembly - SR1530CL/SR1530CLR SATA
View all Intel SR1530HCLS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
Cooling Sub-System Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR 3. Cooling Sub-System The cooling sub-system consists of two 97 x 94 x 33 blower fan, a CPU air duct, and a PS/electronics bay isolation air baffle. The SR1530CL also includes one additional 40 x 40 x 15 PCI cooling fan. These components are used to provide the necessary cooling and airflow to the system. A fan on the processor heat sink is not needed. To maintain the necessary airflow within the system, the air duct and the top cover must be properly installed. Note: The Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCLS and SR1530CLR/SR1530HCLR/SR1530HCLSR do not support redundant cooling. Should a fan blower fail, the system should be powered down as soon as possible to replace the failed fan blower. AF001524 Figure 10. Fan Module Assembly - SR1530CL/SR1530CLR (SATA) 14 Revision 2.2 Intel order number D71005-005