Intel SR1530HCLS Product Specification - Page 39
Environmental and Regulatory Specifications, 9.1 System Level Environmental Limits
![]() |
View all Intel SR1530HCLS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR Environmental and Regulatory Specifications 9. Environmental and Regulatory Specifications 9.1 System Level Environmental Limits The table below defines the system level operating and non-operating environmental limits Table 27. System Environmental Limits Summary Parameter Operating Temperature Non-Operating Temperature Non-Operating Humidity Acoustic noise Shock, operating Shock, unpackaged Shock, packaged Vibration, unpackaged Shock, operating ESD System Cooling Requirement in BTU/Hr Limits +10 C to +35 C with the maximum rate of change not to exceed 10 C per hour -40 C to +70 C 90%, non-condensing at 35 C Sound power: 7.0 BA in an idle state at typical office ambient temperature. (23 +/- 2 degrees C) Half sine, 2 g peak, 11 mSec Trapezoidal, 25 g, velocity change 136 inches/sec (≧40 lbs to > 80 lbs) Non-palletized free fall in height 24 inches (≧40 lbs to > 80 lbs) 5 Hz to 500 Hz, 2.20 g RMS random Half sine, 2 g peak, 11 mSec +/-15kV except I/O port +/-8KV per Intel Environmental test specification 2550 BTU/hour 9.2 Serviceability and Availability The system is designed to be serviced by qualified technical personnel only. The desired Mean Time To Repair (MTTR) of the system is 30 minutes including diagnosis of the system problem. To meet this goal, the system enclosure and hardware have been designed to minimize the MTTR. Following are the maximum times that a trained field service technician should take to perform the listed system maintenance procedures, after diagnosis of the system and having identified the failed component. Remove cover Activity Remove and replace hard disk drive Remove and replace power supply module Remove and replace system fan Remove and replace control panel module Remove and replace baseboard Time Estimate 1 min 5 min 1 min 7 min 2 min 15 min Revision 2.2 31 Intel order number D71005-005
![](/manual_guide/products/intel-sr1530hcls-product-specification-dca1160/39.png)