Intel SR1680MV Service Guide - Page 56
Installing Air Ducts, PCI-E Cage, Removing a PCI-E Cage
![]() |
UPC - 735858210447
View all Intel SR1680MV manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
Installing Air Ducts Reverse the "Removing the IOB Air Duct" steps to install the air duct. PCI-E Cage The left and right I/O board cage modules each include one PCI-E cage. Two PCI-E cages on the server share the same removal and installation procedures. For your reference, this section provides the steps of removing and installing one PCI-E cage on the right I/O board cage module as an example. Figure 42 shows the location of the PCI-E cage on the right I/O board cage module: Figure 42. PCI-E Cage Location Note: Before you remove or install the PCI-E cage, complete the following steps: 1. Make sure the server is not turned on or connected to the AC power. To power off the server, see "Power Off". 2. Remove the left and right I/O board cage modules. To remove the cover, see "Left and Right I/O Board Cage Modules". 3. Disconnect all necessary cable connections. Removing a PCI-E Cage 1. Lift the PCI cage up from the I/O board cage module along the direction of the arrow. 36 Intel® Server System SR1680MV Service Guide
![](/manual_guide/products/intel-sr1680mv-service-guide-802a12d/56.png)