Chapter 2 - Physical Installation • Connect the console cable to J50 on the CPU board and put back the cover over the electronics compartment. Take care so the console cable runs above the ribbon motor (if any) and does not become entangled in the headlift mechanism. • Connect the communication cables to the connectors on the printer's rear plate. • Connect the power cord and switch on the power. • Enter the Setup Mode to set the proper communication parameters for the serial communication channels "uart2:" and "uart3:". Serial interface socket "uart3:" Serial interface socket "uart2:" 8 Double Serial Interface Kit Installation Instructions

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

8
Double Serial Interface Kit Installation Instructions
Chapter 2 — Physical Installation
Connect the console cable to J50 on the CPU board and put back the
cover over the electronics compartment. Take care so the console cable
runs above the ribbon motor (if any) and does not become entangled
in the headlift mechanism.
Connect the communication cables to the connectors on the printer’s
rear plate.
Connect the power cord and switch on the power.
Enter the Setup Mode to set the proper communication parameters
for the serial communication channels "uart2:" and "uart3:".
Serial interface
socket "uart2:"
Serial interface
socket "uart3:"