Intermec PX4i Double Serial Interface Kit Installation Instructions - Page 27

uart4

Page 27 highlights

Chapter 3 - Serial Interface "uart2:", "uart3:", and "uart4:" Connector Configuration (RS-422 Isolated on "uart2:", "uart3:", or "uart4:") DB-9 socket 1 Signal 2 +TXD 3 +RXD 4 - 5 GNDE 6 - 7 -RXD 8 -TXD 9 - Meaning External +5VDC max 500 mA (automatic switchoff at overload, short-circuit protected) provided strap is fitted on J2:A which spoils the galvanical isolation +Transmit data +Receive data Ground -Receive data -Transmit data 5 9 GNDE 4 -TXD 8 -RXD 3 7 +RXD 2 6 +TXD 1 +5V (0.5 A) if GND strap fitted RS-422 socket as seen from the outside. Double Serial Interface Kit Installation Instructions 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Double Serial Interface Kit Installation Instructions
23
Chapter 3 — Serial Interface "uart2:", "uart3:", and "uart4:"
Connector Configuration (RS-422 Isolated on "uart2:", "uart3:", or
"uart4:")
DB-9 socket
Signal
Meaning
1
External +5VDC max 500 mA (automatic switch-
off
at overload, short-circuit protected) provided
strap is fitted on J2:A which spoils the galvanical
isolation
2
+TXD
+Transmit data
3
+RXD
+Receive data
4
5
GNDE
Ground
6
-
7
-RXD
-Receive data
8
-TXD
-Transmit data
9
RS-422 socket as seen from the outside.
4
5
3
2
1
8
9
7
6
+TXD
+5V (0.5 A)
if GND strap
fitted
+RXD
GNDE
-RXD