Intermec PX4i Double Serial Interface Kit Installation Instructions - Page 22

Always start by fitting an interface board in the left-hand slot.

Page 22 highlights

Chapter 2 - Physical Installation • Connect the power cord and switch on the power. • In case the interface board provides additional serial communication ports, enter the Setup Mode to set the proper communication parameters for these ports. Allowed interface combinations (Fingerprint v8.30 or later) Left-hand slot Double Serial Double Serial Double Serial Double Serial Ports uart2: + uart3: uart2: + uart3: uart2: + uart3: uart2: + uart3: Right-hand slot - Double Serial Serial/Industrial IEEE 1284 Ports - uart4: + uart5: uart4: centronics: Serial/Industrial Serial/Industrial Serial/Industrial Serial/Industrial uart2: uart2: uart2: uart2: - Serial/Industrial Double Serial IEEE 1284 - uart3: uart3: + uart4: centronics: IEEE 1284 centronics: - - IEEE 1284 centronics: Double Serial uart2: + uart3: IEEE 1284 centronics: Serial/Industrial uart2: Remarks: • The left-hand slot is the slot closest to the center section. • Always start by fitting an interface board in the left-hand slot. • RS-485 is only supported by "uart2:" "uart3:" "uart5:" "uart2:" "uart4:" 18 Double Serial Interface Kit Installation Instructions

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

18
Double Serial Interface Kit Installation Instructions
Chapter 2 — Physical Installation
Connect the power cord and switch on the power.
In case the interface board provides additional serial communication
ports, enter the Setup Mode to set the proper communication param-
eters for these ports.
Allowed interface combinations (Fingerprint v8.30 or later)
Left-hand slot
Ports
Right-hand slot
Ports
Double Serial
uart2: + uart3:
Double Serial
uart2: + uart3:
Double Serial
uart4: + uart5:
Double Serial
uart2: + uart3:
Serial/Industrial
uart4:
Double Serial
uart2: + uart3:
IEEE 1284
centronics:
Serial/Industrial
uart2:
Serial/Industrial
uart2:
Serial/Industrial
uart3:
Serial/Industrial
uart2:
Double Serial
uart3: + uart4:
Serial/Industrial
uart2:
IEEE 1284
centronics:
IEEE 1284
centronics:
IEEE 1284
centronics:
Double Serial
uart2: + uart3:
IEEE 1284
centronics:
Serial/Industrial
uart2:
Remarks:
°e left-hand slot is the slot closest to the center section.
Always start by fitting an interface board in the left-hand slot.
• RS-485 is only supported by "uart2:"
"uart3:"
"uart5:"
"uart2:"
"uart4:"