JVC DT100U Instruction Manual - Page 51

Electronic Program Guide (EPG), Easy Record Timer

Page 51 highlights

Electronic Program Guide (EPG) This VCR allows you to set recording timer or viewing timer by selecting the program from the Electronic Program Guide (EPG). • Turn on the VCR and the TV, and select the AV mode on the TV. • Set the [VCR/TV/CABLE/DBS] selector on the Remote to [VCR]. VCR CABLE TV /DBS [EPG] EN 51 A Easy Record Timer 1 Access EPG screen Press [EPG]. • The clock must be set to access the EPG screen. If you have not set the clock, an error message will be displayed. Refer to page 15 for the clock setting procedure. • When the received channel is not a digital (DTV) channel, "CAN NOT SET ON THIS CHANNEL SELECT DTV CHANNEL THEN RETRY" appears on the screen. • When receiving digital broadcast, if [EPG] is pressed to access the EPG screen at the same instant a blocked program or scene is received, the EPG screen will not be displayed. In addition, if a blocked program or scene is received while the EPG screen is being displayed, the sub picture screen will turn black. 2 Select time zone and channel Press [D E] to select the desired time zone, and [FG] to select the desired channel, then press [OK]. • The detail information of the program will appear. A-2,3 B-2,3 C-2,3 D-2,3 ATTENTION: When setting recording timer of a digital (ATSC) program, the VCR must be set to the standby mode condition 10 minutes before the start time of a program. As timer recording is performed based on the time information of each program, timer standby and timer recording may not be possible due to deviation in the timer information of each program if the VCR is set to standby mode within 10 minutes of the program start time. In such cases, press [REC] to perform manual recording. NOTES: • The EPG function works only when receiving digital programs. • If the Easy Rec Timer or Easy View Timer is set for a program whose start time has passed, a message "Check Start Time" appears on the screen. In this case, exit the EPG screen and perform manual recording. 3 Set record timer Press [D] to move the arrow to "Easy Rec", then press [OK]. • The timer is set. An mark appears in front of the program title. 4 Return to normal screen Press [EPG]. 5 Engage timer recording standby mode Press [TIMER (j)]. The VCR turns off automatically and [j] is displayed on the front display panel. To use the VCR while it is in timer recording standby mode Press [TIMER (j)] to cancel the timer recording standby mode, then press [POWER] to turn on the VCR. DO NOT forget to put the VCR into timer recording standby mode again by pressing [TIMER (j)] after you use the VCR; otherwise, you cannot record the broadcasts you want. • When "AUTO TIMER" (A page 68) is set to "ON", the timer recording standby mode is automatically engaged when the VCR is turned off. It is temporarily canceled when the VCR is turned on. You do not have to press [TIMER (j)] to engage or disengage the timer recording standby mode.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

EN
51
Electronic Program
Guide (EPG)
This VCR allows you to set recording timer or viewing timer by
selecting the program from the Electronic Program Guide (EPG).
NOTES:
• The EPG function works only when receiving digital programs.
• If the Easy Rec Timer or Easy View Timer is set for a program
whose start time has passed, a message “Check Start Time”
appears on the screen. In this case, exit the EPG screen and
perform manual recording.
A
Easy Record Timer
1
Access EPG screen
Press [EPG].
The clock must be set to access the EPG screen. If you
have not set the clock, an error message will be
displayed. Refer to page 15 for the clock setting
procedure.
When the received channel is not a digital (DTV)
channel, “CAN NOT SET ON THIS CHANNEL SELECT
DTV CHANNEL THEN RETRY” appears on the screen.
When receiving digital broadcast, if [EPG] is pressed to
access the EPG screen at the same instant a blocked
program or scene is received, the EPG screen will not
be displayed.
In addition, if a blocked program or scene is received
while the EPG screen is being displayed, the sub
picture screen will turn black.
2
Select time zone and channel
3
Set record timer
4
Return to normal screen
Press [EPG].
5
Engage timer recording standby mode
Press [TIMER (
j
)].
The VCR turns off automatically and [
j
] is
displayed on the front display panel.
To use the VCR while it is in timer recording standby mode
Press [TIMER (
j
)] to cancel the timer recording standby
mode, then press [POWER] to turn on the VCR.
DO NOT forget to put the VCR into timer recording
standby mode again by pressing [TIMER (
j
)] after you use
the VCR; otherwise, you cannot record the broadcasts
you want.
• When “AUTO TIMER” (
A
page 68) is set to “ON”, the
timer recording standby mode is automatically engaged
when the VCR is turned off. It is temporarily canceled
when the VCR is turned on. You do not have to press
[TIMER (
j
)] to engage or disengage the timer recording
standby mode.
Turn on the VCR and the TV, and select the AV
mode on the TV.
Set the [VCR/TV/CABLE/DBS] selector on the
Remote to [VCR].
ATTENTION:
When setting recording timer of a digital (ATSC) program, the
VCR must be set to the standby mode condition 10 minutes
before the start time of a program.
As timer recording is performed based on the time
information of each program, timer standby and timer
recording may not be possible due to deviation in the timer
information of each program if the VCR is set to standby
mode within 10 minutes of the program start time. In such
cases, press [REC] to perform manual recording.
A
-2,3
B
-2,3
C
-2,3
D
-2,3
VCR
TV
CABLE
/DBS
[EPG]
Press [
D E
] to select the
desired time zone, and
[
FG
] to select the desired
channel, then press [OK].
The detail information of
the program will appear.
Press [
D
] to move the
arrow to “Easy Rec”,
then press [OK].
The timer is set. An
mark appears in front
of the program title.