6. SETTING AND ADJUSTMENTS BEFORE SHOOTING 6-9 Monitoring Audio during Recording ALARM control FILTER 1 3200k 2 5600k 3 5600k+ND SHUTTER STATUS MENU ALARM MONITOR AUTO IRIS FULL AUTO BLACK BACK L NORMAL SPOT L STRETCH NORMAL COMPRESS LOLUX PRST A B AUTO OKFNFEE BARS CAM ON HML SAVE STBY VTR GAIN OUTPUT WHT.BAL NG POWER ON OFF OPERATE/WARNING RESET MONITOR SELECT CH-1 AUDIO CH-2 LEVEL LIGHT ON OFF COUNTER CTL TC UB MONITOR control MONITOR SELECT switch Monitoring loudspeaker EARPHONE jack The audio input during recording, in record-pause or stop mode can be monitored through the monitoring loudspeaker or earphone. • The monitoring audio is not output from the loudspeaker while the EARPHONE jack is in use. • Select the audio channel to be monitored using the MONITOR SELECT switch. CH-1 : The sound input to the CH-1 channel is output. MIX : The sound input to the CH1 and CH2 channels is output mixed. CH-2 : The sound input to the CH-2 channel is output. • The MONITOR volume control adjusts the monitoring volume. • The loudspeaker or earphone outputs an alarm tone in the case of an abnormal condition occurring in the unit. An alarm tone is also output when the tape end is reached or when the battery is running down. The alarm tone volume can be adjusted with the ALARM control. For details on the alarm tone, see page 87. * Do not increase the audio monitoring volume excessively; otherwise howling with the camera microphone may occur. 7. SHOOTING OPERATION 7-1 Basic Recording Operation 1. "DEW" 3. EJECT CH 1 CH 2 40 30 20 10 32k 48k AUD LOCK SP MENU H OVER AUTO OFF DEW 0 dB OVER SERVO RF L i PB NDF HOLD M S F Eject switch 5. FILTER 1 3200k 2 5600k 3 5600k+ND SHUTTER STATUS MENU ALARM MONITOR AUTO IRIS FULL AUTO BLACK BACK L NORMAL SPOT L STRETCH NORMAL COMPRESS LOLUX PRST A B ON KNEE OFF AUTO BARS CAM HML SAVE STBY VTR GAIN OUTPUT WHT.BAL NG POWER ON OFF OPERATE/WARNING RESET MONITOR SELECT CH-1 AUDIO CH-2 LEVEL LIGHT ON OFF COUNTER CTL TC UB OFF ZEBRA SKIN AREA AUTO WHITE ACCU FOCUS VTR AUDIO LEVEL CH-1 TAKE 6. 2. 4. PRST A B ON KNEE OFF AUTO BARS CAM HML SAVE STBY VTR GAIN OUTPUT WHT.BAL NG POWER ON OFF 1. Set the POWER switch to ON. Power is supplied to the unit. Check that the condensation indicator "DEW" does not appear on the display. If it is lit, wait until the indicator goes out. 2. Set the VTR switch to the STBY position. Even when the VTR switch is set to the "SAVE" position, pressing the VTR trigger button will start recording. However, in this case, it is necessary to wait a short time until the recording actually starts. For details on the VCR SAVE mode, see page 52. 3. Slide the EJECT switch to open the cassette cover. • Ensure that the switch on the back of the videocassette is set to REC and insert the cassette correctly. When the cassette is inserted, the tape is loaded and the unit enters the record-pause mode. • Slowly close the cassette cover. • Use a videocassette marked MiniDV. • If the cassette cover is not closed, the GY-DV500 will remain inoperative. • At the loading time and power switch set to on time, the built-in head cleaner will emit a sound while operating. This does not indicate a malfunction. • After the cassette cover is closed, it takes about 8 seconds before the unit is ready for recording. 1. RET M A W T 4. 7. 4. Set the switches as required. • GAIN : Sensitivity suitable for the subject • OUTPUT : "CAM/AUTO KNEE ON" • WHT-BAL : "A" or "B" • Set the IRIS switch of the lens to "A". 5. Select the FILTER according to the lighting condition. Position 1 (3200K) : For shooting indoors or outdoors when illumination is not sufficient Position 2 (5600K) : For shooting outdoors Position 3 (5600K + ND): For shooting outdoors under a clear sky. 6. Adjust the white balance. See "White Balance Adjustment" on page 45. 7. Point the camera at the subject and determine the angle of view and focus with the zoom lever and the focusing ring. MACRO 49 50

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

49
6. SETTING AND ADJUSTMENTS BEFORE SHOOTING
LIGHT
ON
OFF
COUNTER
CTL
TC
UB
RESET
OPERATE/WARNING
MONITOR
SELECT
STATUS
SHUTTER
MENU
FILTER
1
3200k
2
5600k
3
5600k+ND
POWER
NG
GAIN
OUTPUT
WHT.BAL
VTR
ON
OFF
ALARM
MONITOR
CH-1
CH-2
AUDIO
LEVEL
MONITOR SELECT
switch
EARPHONE
jack
Monitoring
loudspeaker
ALARM
control
MONITOR
control
The audio input during recording, in record-pause or stop mode
can be monitored through the monitoring loudspeaker or
earphone.
The monitoring audio is not output from the loudspeaker while
the EARPHONE jack is in use.
Select the audio channel to be monitored using the MONITOR
SELECT switch.
CH-1
: The sound input to the CH-1 channel is output.
MIX
: The sound input to the CH1 and CH2 channels is
output mixed.
CH-2
: The sound input to the CH-2 channel is output.
The MONITOR volume control adjusts the monitoring
volume.
The loudspeaker or earphone outputs an alarm tone in the
case of an abnormal condition occurring in the unit.
An alarm tone is also output when the tape end is reached
or when the battery is running down. The alarm tone volume
can be adjusted with the ALARM control. For details on the
alarm tone, see page 87.
* Do not increase the audio monitoring volume excessively;
otherwise howling with the camera microphone may
occur.
6-9
Monitoring Audio during Recording
50
7. SHOOTING OPERATION
M
RET
W
T
A
MACRO
4.
7.
LIGHT
COUNTER
RESET
OPERATE/WARNING
MONITOR
SELECT
STATUS
SHUTTER
MENU
FILTER
1
3200k
2
5600k
3
5600k+ND
POWER
NG
GAIN
OUTPUT
WHT.BAL
VTR
ALARM
MONITOR
5.
3.
H
M
S
F
AUD LOCK
32k
CH 1
CH 2
48k
PB
NDF
AUTO OFF
DEW
L i
RF
SERVO
HOLD
SP
MENU
OVER
OVER
40 30
20
10
0
dB
1.
DEW
EJECT
AUTO
WHITE
SKIN
AREA
ACCU
FOCUS
TAKE
VTR
ZEBRA
AUDIO
LEVEL CH-1
OFF
6.
POWER
NG
GAIN
OUTPUT
WHT.BAL
VTR
ON
OFF
HML
SAVE STBY
BARS CAM
ON
OFF
AUTO KNEE
PRST A B
2.
4.
1.
7-1
Basic Recording Operation
1.
Set the POWER switch to ON.
Power is supplied to the unit.
Check that the condensation indicator "DEW" does not
appear on the display. If it is lit, wait until the indicator goes
out.
2.
Set the VTR switch to the STBY position.
Even when the VTR switch is set to the "SAVE" position,
pressing the VTR trigger button will start recording.
However, in this case, it is necessary to wait a short time
until the recording actually starts.
For details on the VCR SAVE mode, see page 52.
3.
Slide the EJECT switch to open the cassette cover.
Ensure that the switch on the back of the videocassette
is set to REC and insert the cassette correctly.
When the cassette is inserted, the tape is loaded and
the unit enters the record-pause mode.
Slowly close the cassette cover.
Use a videocassette marked MiniDV.
If the cassette cover is not closed, the GY-DV500 will
remain inoperative.
At the loading time and power switch set to on time,
the built-in head cleaner will emit a sound while
operating. This does not indicate a malfunction.
After the cassette cover is closed, it takes about 8
seconds before the unit is ready for recording.
Eject switch
4.
Set the switches as required.
GAIN
: Sensitivity suitable for the subject
OUTPUT
: "CAM/AUTO KNEE ON"
WHT-BAL
: "A" or "B"
Set the IRIS switch of the lens to "A".
5.
Select the FILTER according to the lighting condition.
Position 1 (3200K)
: For shooting indoors or outdoors when
illumination is not sufficient
Position 2 (5600K)
: For shooting outdoors
Position 3 (5600K + ND):
For shooting outdoors under a clear
sky.
6.
Adjust the white balance.
See "White Balance Adjustment" on page 45.
7.