13 MEMORY FEATURES STORING FREQUENCY RANGES Memory channels 290 to 299 allow you to store frequency ranges for VFO tuning and Program Scan. Program Scan is described in the next chapter. To tune or scan frequencies within a specified range, store the start and end frequencies for that range in advance. 1 Press [A/B] to select VFO A or VFO B. 2 Select the desired start frequency. 3 Press [M.IN] to enter Memory Scroll mode. • To exit Memory Scroll mode and abort the storage process, press [CLR]. 4 Turn the MULTI/ CH control, or press Mic [UP]/ [DWN] to select a memory channel in the range of 290 to 299. • You can also select a channel by entering a 3-digit number, such as 290, using the numeric keys. 5 Press [M.IN] to store the start frequency in the memory channel. • "CLOSE INPUT" appears on the sub dot-matrix display. 1 Press [VFO/M] to enter Memory Recall mode. 2 Turn the MULTI/ CH control, or press Mic [UP]/ [DWN] to select a memory channel from 290 to 299. Now you can only tune from the start frequency to the end frequency, using the Tuning control. Note: Pressing Mic [UP]/ [DWN] or turning the MULTI/ CH control results changing the memory channel number while in Programmable VFO mode. Memory Channel Lockout You can lock out memory channels that you prefer not to monitor during Memory Scan. Memory Scan is described in the next chapter {page 68}. 1 Press [VFO/M] to enter Memory Recall mode. 2 Turn the MULTI/ CH control, or press Mic [UP]/ [DWN] to select the memory channel. 3 Press [CLR] momentarily. • Pressing [CLR] for more than approximately 2 seconds erases the contents of the memory channel. • A dot appears beside the right-most digit of the memory channel number to indicate the channel has been locked out. 6 Turn the Tuning control or the MULTI/ CH control to select the end frequency. 7 Press [M.IN] to store the end frequency in the memory channel. • The previous data stored in the channel is overwritten. ■ Confirming Start/End Frequencies Use this procedure to check the start and end frequencies that you stored in channels 290 to 299. 1 Press [VFO/M] to enter Memory Recall mode. 2 Turn the MULTI/ CH control, or press Mic [UP]/ [DWN] to select a memory channel from 290 to 299. 3 Press [-] to check the start frequency and [+] to check the end frequency. ■ Programmable VFO Using the start and end frequencies that you stored in channels 290 to 299, Programmable VFO restricts the frequency range that you can tune with the Tuning control. One application of this function is to help you operate within the authorized frequency limits of your license. • Repeatedly pressing [CLR] toggles between adding and removing the channel from the scan list. ERASING MEMORY CHANNELS If there are memory channels that you will not recall in the future, you may prefer erasing the contents of those channels. 1 Press [VFO/M] to enter Memory Recall mode. 2 Turn the MULTI/ CH control, or press Mic [UP]/ [DWN] to select the memory channel. • You can also select a channel by entering a 3-digit number, such as 012, using the numeric keys. 3 Press and hold [CLR] for approximately two seconds. • A long beep sounds to confirm that the channel data has been erased. 62
![](/manual_guide/products/kenwood-ts2000-operation-manual-ab192f5/72.png)