LG LSC27914ST Owner's Manual - Page 108
Poor Cooling in Freezer
View all LG LSC27914ST manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 108 highlights
17) Poor Cooling in Freezer section NO. CHECKING FLOW Check the conditions of gasket in freezer door (gaps, damage, deformed). 1 Check the sensor resistance value in CON 6. 2 RESULT & SERVICE ACTION Result Ok Abnormal Service Action Go to Step 2 Fix up (if possible) or change the Gasket Refer to temperature chart for Refrigerator Sensor. Result Service Action Ok Go to Step 3 Abnormal Check section "3" Abnormal Freezer Sensor Reset product, then, enter to TEST MODE 1 (Press once). 3 ALL LED ON 1) Open freezer door. 2) Press manually the freezer door S/W. 3) Check the air flow. 4 Result Entered Not entered Service Action Go to Step 4 Execute DISPLAY CHECK MODE, check the result and match with related error Result Air flow No Air flow Service Action Go to Step 5 Go to Step 6 1) Enter to TEST MODE 2. 2) Open freezer door. 5 3) Press manually the freezer door S/W. 4) Check the air flow. Result Air flow No Air flow Service Action Go to Step 10 Go to Step 6 - 107 -