LG LSC27914ST Owner's Manual - Page 111
Over cooling in Refrigerator
View all LG LSC27914ST manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 111 highlights
18) Over cooling in Refrigerator section NO. CHECKING FLOW Check the sensor resistance value in CON 7. 1 RESULT & SERVICE ACTION Refer to Temperature chart for Refrigerator Sensor. Result Service Action OK Go to Step 2 Abnormal Check Section 3 Abnormal Refrigerator Sensor 2 Enter to TEST MODE 1 (Press once the TEST S/W in Main PCB). 1) Open Refrigerator door. 2) Press manually the refrigerator door S/W, wait 10 seconds. 3) Check the air flow. 3 Go to Step 3 Result Air flow No Air flow Service Action Go to Step 4 Go to Step 6 4 Enter to TEST MODE 2 (Press once the TEST S/W in Main PCB). 1) Open Refrigerator door. 2) Press manually the refrigerator door S/W. 5 3) Check the air flow. 6 Turn Off the refrigerator. 1) Remove Control Box in refrigerator sensor. 7 2) Check for any loose connection. Go to Step 5 Result Air flow No Air flow Service Action Go to Step 6 Go to Step 10 Go to Step 7 Connectors must be firmly connected, and wires don't be have any damage. Next action: Go to Step 8. 3) Turn On the refrigerator. - 110 -