LG LSC27914ST Owner's Manual - Page 85
Abnormal Room Temperature Sensor Error
View all LG LSC27914ST manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 85 highlights
5) Abnormal Room Temperature Sensor Error NO. CHECKING FLOW Check for a loose connection in CON5. 1 RESULT & SERVICE ACTION Result Firmly plugged Loose Service Action Go to Step 2 Unplug connector in CON 5 and check between White to White as is shown in the picture. 2 Result 0 Ù Short OFF Open Other Normal Service Action Change the sensor Replace Product Check the Temperature and Resistance (Temperature Chart #3) - 84 -
5) Abnormal Room Temperature Sensor Error
CHECKING FLOW
RESULT & SERVICE ACTION
Check for a loose connection in CON5.
Unplug connector in CON 5 and check between
White to White
as is shown in the picture.
Result
Service Action
Firmly plugged
Loose
Go to Step 2
Result
Service Action
0
Ù
OFF
Change the sensor
Replace Product
Other
Short
Open
Normal
Check the Temperature
and Resistance
(Temperature Chart #3)
1
2
NO.
- 84 -