Page 57 highlights

3. Type the date and time in the appropriate fields. 4. Refer to "Exiting from the Configuration/Setup Utility Program" on page 41 for instructions on saving your settings and exiting from the Configuration/Setup Utility program. Your operating system might also have a function for setting the date and time. Refer to your operating system documentation for more information. Changing Plug and Play Control Features If you are installing a Plug and Play adapter or other device and experience problems, you might need to change certain settings in Plug and Play Control in the Configuration/Setup Utility program. Note: If you experience any error message related to Plug and Play adapters or devices, see "POST Message Charts" on page 71 for complete information on solving the problem. A setting that might affect the way a Plug and Play adapter behaves is the Address Decode setting. Most Plug and Play adapters use 16-bit address decoding (this is the default setting for Address Decode.). Some Plug and Play adapters have not fully implemented this addressing scheme. If you are experiencing problems with a Plug and Play adapter, changing the address decoding to 10-bit might fix the problem. Conversely, if you are experiencing an 1852 error message, changing the address decode setting to 16-bit might fix the problem. Another setting that affects any type of Plug and Play device is the Plug and Play Operating System setting. If you install a Plug and Play adapter or device and experience a 185x error message, and your computer will be loading a Plug and Play-compliant operating system, set this value to Yes. Note: Check your operating system documentation to determine if it supports this function. The 185x error messages occur because the computer is unable to configure all adapters and devices in the system due to conflicting resource assignments. Selecting Yes allows the configuration of Plug and Play devices to be performed by the operating system. To change Plug and Play control settings, select Advanced Setup and then Plug and Play Control. The next menu displays Address Decode and Plug and Play Operating System. Chapter 4. Configuring Your Computer. 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

3.
Type the date and time in the appropriate fields.
4.
Refer to “Exiting from the Configuration/Setup Utility Program” on page
41 for
instructions on saving your settings and exiting from the Configuration/Setup
Utility program.
Your operating system might also have a function for setting the date and time.
Refer to your operating system documentation for more information.
Changing Plug and Play Control Features
If you are installing a Plug and Play adapter or other device and experience
problems, you might need to change certain settings in Plug and Play Control in the
Configuration/Setup Utility program.
Note:
If you experience any error message related to Plug and Play adapters or
devices, see “POST Message Charts” on page
71 for complete information on
solving the problem.
A setting that might affect the way a Plug and Play adapter behaves is the Address
Decode setting.
Most Plug and Play adapters use 16-bit address decoding (this is
the default setting for Address Decode.).
Some Plug and Play adapters have not
fully implemented this addressing scheme.
If you are experiencing problems with a
Plug and Play adapter, changing the address decoding to
10-bit
might fix the
problem.
Conversely, if you are experiencing an 1852 error message, changing the
address decode setting to
16-bit
might fix the problem.
Another setting that affects any type of Plug and Play device is the Plug and Play
Operating System setting.
If you install a Plug and Play adapter or device and
experience a 185
x
error message, and your computer will be loading a Plug and
Play-compliant operating system, set this value to
Yes
.
Note:
Check your operating system documentation to determine if it supports this
function.
The 185
x
error messages occur because the computer is unable to configure all
adapters and devices in the system due to conflicting resource assignments.
Selecting
Yes
allows the configuration of Plug and Play devices to be performed by
the operating system.
To change Plug and Play control settings, select
Advanced Setup
and then
Plug and
Play Control
.
The next menu displays
Address Decode
and
Plug and Play
Operating System
.
Chapter
4.
Configuring Your Computer.
43