Lenovo ThinkCentre A58 User Manual - Page 81
Assure Asset Security Enabled, Diskette Drive Cable
View all Lenovo ThinkCentre A58 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
Diagnostic error code 175-198-XXX Thermal Sensor(s) test aborted 175-199-XXX Thermal Sensor(s) test failed, cause unknown 175-250-XXX 175-251-XXX Thermal Sensor(s) limit error 185-000-XXX Asset Security Test Passed 185-XXX-XXX Asset Security failure 185-278-XXX Asset Security Chassis Intrusion 201-000-XXX System Memory Test Passed 201-XXX-XXX System Memory error 202-000-XXX System Cache Test Passed 202-XXX-XXX System Cache error 206-000-XXX Diskette Drive Test Passed 206-XXX-XXX Diskette Drive error 215-000-XXX CD-ROM Drive Test Passed FRU/Action 1. If a component is called out, make sure it is connected and/or enabled 2. Flash the system and re-test. See "Updating (flashing) BIOS from a disc" on page 278 3. Go to "Undetermined problems" on page 81 1. See "Undetermined problems" on page 81 2. Flash the system and re-test. See "Updating (flashing) BIOS from a disc" on page 278 3. Replace component under function test 1. Check fans 2. Check Power supply voltages 3. Microprocessor 4. System board No action 1. Flash system 2. System board 1. Assure Asset Security Enabled 2. C2 Cover Switch 3. System board No action 1. Replace the memory module called out by the test 2. System board No action 1. Cache, if removable 2. System board 3. Microprocessor No action 1. Diskette Drive Cable 2. Check power supply voltages 3. Diskette drive 4. System board No action Chapter 7. Symptom-to-FRU index 75