Maytag MEDB800VQ Use and Care Guide - Page 14
shown.
UPC - 883049140506
View all Maytag MEDB800VQ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
3. Connect the other wires to outer terminal block screws. Tighten screws. ! !! 2. Place the hooked end of the neutral wire (white or center wire) of direct wire cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw. 4. Tighten strain relief screws. 5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold- down screw. 6° You have completed your electrical connection. Now go to "Venting Requirements." 3-wire connection: Direct Wire Use where local codes permit connecting cabinet-ground conductor to neutral wire. Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed. Strip 31/2'' (89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape ends of wires into a hook shape. -m ........... .2 A. External ground conductor screw B. Neutral ground wire C. Center silver-colored terminal block screw D. Neutral wire (white or center wire) E. 3/4" ( 19 ram) UL listed strain relief 3. Place the hooked ends of the other direct wire cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws. !! !! When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown. 4. Tighten strain relief screw. 5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold- down screw. 6. You have completed your electrical connection. Now go to "Venting Requirements." 1. I.oosen or remove center silver-colored terminal block screw. 14