Panasonic WVCS564 WVCS564 User Guide - Page 39

RS485 SETUP, Initial Camera Communication Parameters

Page 39 highlights

How to Reset to the Factory Preset Parameters Any of the above settings plus the ALC/MANUAL level control and phase adjustments can be reset to the factory preset parameters by placing the cursor over the desired mode and then press the F2 button of the WV-CU550B. (For the WV-RM70, keep pressing the Right and Left switches simultaneously for 2 seconds or more.) s RS485 Setup q Initial Camera Communication Parameters In an RS485 chain the matrix switcher, PC, controllers and cameras should be set to the same protocol and parameters for communication. Confirm the system protocol and parameters prior to setting the communication parameters for the camera. The initial communication parameters are shown on the RS485 setup menu below. Other than the onscreen-setup parameters, the 4-bit DIP switch may be used to select 2-line (Half Duplex) or 4-line (Full Duplex) communication. q Changing the Camera Communication Parameters You can remote control this camera by using a specified extension unit such as a computer with a modem. 1. Display the SET UP MENU. Move the cursor to RS485 SET UP and press the CAM (SET) key. RS485 SET UP menu appears on the monitor. 2. Move the cursor to the item and select the parameter by moving the joystick to the right or left. RS485 Setup menu ** RS485 SET UP ** UNIT NUMBER 1 SUB ADDRESS ----- BAUD RATE 19200 DATA BIT 8 PARITY CHECK NONE STOP BIT 1 XON/XOFF NOT USE WAIT TIME OFF ALARM DATA --- DELAY TIME --- RET Unit Number (UNIT NUMBER) Displays the unit number set by the DIP switch. If the switch is set to 1-96, select a number by moving the joystick to the right or left. In an RS485 chain each unit must have a unique number. Default: 1. See INSTALLATION for DIP switch setting. Sub Address (SUB ADDRESS) Do not set. Baud Rate (BAUD RATE) Specifies the transmission speed (2 400, 4 800, 9 600, 19 200 bit per second) for the RS485 communication. The factory setting is 19 200. Data Bit (DATA BIT) Specifies the number of data bits (7 or 8 bits) for the RS485 communication. The factory setting is 8. Parity Check (PARITY CHECK) Specifies the parity check mode (NONE, ODD, EVEN). The factory setting is NONE. Stop Bit (STOP BIT) Specifies the number of stop bits (1 or 2 bits). The factory setting is 1. 40

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

40
How to Reset to the Factory Preset Parameters
Any of the above settings plus the ALC/MANUAL level control and phase adjustments can be reset to the
factory preset parameters by placing the cursor over the desired mode and then press the F2 button of
the WV-CU550B. (For the WV-RM70, keep pressing the Right and Left switches simultaneously for 2 sec-
onds or more.)
RS485 Setup
Initial Camera Communication Parameters
In an RS485 chain the matrix switcher, PC, controllers and cameras should be set to the same protocol
and parameters for communication. Confirm the system protocol and parameters prior to setting the com-
munication parameters for the camera.
The initial communication parameters are shown on the RS485 setup menu below. Other than the on-
screen-setup parameters, the 4-bit DIP switch may be used to select 2-line (Half Duplex) or 4-line (Full
Duplex) communication.
Changing the Camera Communication Parameters
You can remote control this camera by using a specified extension
unit such as a computer with a modem.
1.
Display the SET UP MENU. Move the cursor to RS485 SET UP
and press the CAM (SET) key. RS485 SET UP menu appears on the
monitor.
2.
Move the cursor to the item and select the parameter by moving the
joystick to the right or left.
Unit Number (UNIT NUMBER)
Displays the unit number set by the DIP switch. If the switch is set to 1-96, select a number by moving the
joystick to the right or left. In an RS485 chain each unit must have a unique number.
Default: 1. See INSTALLATION for DIP switch setting.
Sub Address (SUB ADDRESS)
Do not set.
Baud Rate (BAUD RATE)
Specifies the transmission speed (2 400, 4 800, 9 600, 19 200 bit per second) for the RS485 communica-
tion. The factory setting is 19 200.
Data Bit (DATA BIT)
Specifies the number of data bits (7 or 8 bits) for the RS485 communication. The factory setting is 8.
Parity Check (PARITY CHECK)
Specifies the parity check mode (NONE, ODD, EVEN). The factory setting is NONE.
Stop Bit (STOP BIT)
Specifies the number of stop bits (1 or 2 bits). The factory setting is 1.
** RS485 SET UP **
UNIT NUMBER
SUB ADDRESS
BAUD RATE
DATA BIT
PARITY CHECK
STOP BIT
XON/XOFF
WAIT TIME
ALARM DATA
DELAY TIME
RET
1
-----
19200
8
NONE
1
NOT USE
OFF
---
---
RS485 Setup menu