Commissioning, machine, Switching, on/off
View all Pfaff 1245 - 1246 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
Mounting and commissioning the machine 8.02 Commissioning the machine • Before commissioning the machine, check the electrical leads and pneumatic hoses for any damage. • Remove pin 1 of the oil reservoir 2 (Fig. S - 06). The pin serves only to protect the machine from damage during transport and must not be used when sewing. • Clean the machine thoroughly and oil it (see chapter 10 Care and maintenance) • Have specialists ensure that the machine's motor can be operated with the available electricity supply and that it is connected correctly to the terminal box. If not, the machine must not be operated. • The handwheel must rotate towards the operator when the machine is running, if not, have the motor re-adjusted converted by a specialist. • Connect the machine to the compressed air system. The pressure gauge must display a pressure of approx. 6 bar. If not, adjust the pressure to this value (see chapter 10.07 Checking the air pressure>. Fig. 8-06 803 Switching the machine on/off • Switch on the machine (see chapter 7.01). • Carry out a test run. FAFF 8-5