Pfaff 1245 - 1246 Owner's Manual - Page 59
handwheel.
View all Pfaff 1245 - 1246 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
Adjustment 11.0502 Tripping lever Requirement In needle rise position, the flattened pin of control lever 6 (see arrow) must fall slightly into the track of control cam 7 when activating lever 8 is activated. ° 7\N F9 ,i 11-18 • Screw out screw 1 and swing out connecting rod 2. • Loosen screws 3 and 4. • Bring the needle bar to needle rise position by turning the handwheel. • Bring clamp 5 to rest on the right side of the housing. • Keeping this position, move control lever 6 laterally in accordance with the requirement and then press control lever 6 onto the bottom of the cam track. • In this position, tighten screw 3. • Carry out a check in accordance with the requirement. • Screw 4 remains loosened until the release trip is adjusted. 11 - 21