Sanyo 24KHS72 Service Manual - Page 101
Risk of Electric Shock
![]() |
View all Sanyo 24KHS72 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 101 highlights
To unmount indoor unit Press the 2 L marks on the lower part of the indoor unit and unlatch the tabs. Then lift the indoor unit and unmount. (Fig. 42) 3-10. Drain Hose a) The drain hose should be slanted downward to the outdoors. (Fig. 43) b) Never form a trap in the course of the hose. c) If the drain hose will run in the room, insulate the hose with insulation* so that chilled condensation will not damage furniture or floors. (Fig. 44) * Foamed polyethylene or its equivalent is recommended. WARNING Do not supply power to the unit or operate it until all tubing and wiring to the outside unit are completed. Risk of Electric Shock Push Fig. 42 Slant Indoor unit Drain hose Fig. 43 Condensation Insulation material (Locally purchased) must be used. Fig. 44 15