Sanyo 24KHS72 Service Manual - Page 31
Electrical Data
View all Sanyo 24KHS72 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
6. ELECTRICAL DATA 6-1. Electrical Characteristics Indoor Unit KHS1872 Outdoor Unit CH1872 (1) Voltage:230V Cooling Performance at Rating conditions Running amp. A Power input W Indoor Unit Fan Motor 0.3 32 Outdoor Unit Fan Motor + Compressor 230V Single-phase 60Hz 6.7 1,468 Rating conditions: Indoor air temperature: 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B. Outdoor air temperature: 95°F (35°C) D.B. Heating Performance at Rating conditions Rating conditions: Running amp. Power input Indoor air temperature Outdoor air temperature Indoor Unit Outdoor Unit Fan Motor Fan Motor + Compressor 230V Single-phase 60Hz A 0.3 7.1 W 34 1,541 70°F (21.1°C) D.B. 47°F (8.3°C) D.B. / 43°F (6.1°C) W.B. < 230V > Complete Unit 7.0 1,500 Complete Unit 7.4 1,575 (2) Voltage:208V Cooling Performance at Rating conditions Running amp. A Power input W Indoor Unit Fan Motor 0.3 32 Outdoor Unit Fan Motor + Compressor 208V Single-phase 60Hz 7.4 1,468 Rating conditions: Indoor air temperature: 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B. Outdoor air temperature: 95°F (35°C) D.B. Heating Performance at Rating conditions Rating conditions: Running amp. Power input Indoor air temperature Outdoor air temperature Indoor Unit Outdoor Unit Fan Motor Fan Motor + Compressor 208V Single-phase 60Hz A 0.3 7.8 W 34 1,541 70°F (21.1°C) D.B. 47°F (8.3°C) D.B. / 43°F (6.1°C) W.B. < 208V > Complete Unit 7.7 1,500 Complete Unit 8.1 1,575 31