Page 13 highlights
Outdoor Unit CH2472 Control PCB Part No. Controls Control Circuit Fuse Compressor Type Compressor Model / Nominal Output Compressor Oil ... Amount Pints (cc) Coil Resistance (Ambient Temp. 68 °F (20 °C)) Ohm Safety Device CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Overload Relay Model Operation Temp. Run Capacitor Micro F VAC Crankcase Heater Fan Type Q'ty ... Dia. inch (mm) Fan Motor Type Model ... Q'ty No. of Poles Rough Measure RPM (Cool / Heat) Nominal Output Coil Resistance (Ambient Temp. 68 °F (20 °C)) Safety Device Type Over- Current Protection Over- Heat Protection Run Capacitor W Ohm Micro F VAC Heat Exchanger Coil Coil Rows Fins per inch Face Area ft2 (m2) External Finish CB-CH2472 Microprocessor 250V 25A DC Twin Rotary (Hermetic) G8T265FU1JW / 2,410W FV50S ... 1.49 (700) U - V : 0.36 V - W : 0.36 W - U : 0.36 Yes Yes Yes CS-7L115 Open : 239 °F (115 °C), Close : 203 °F (95 °C) 230V 30W Propeller 1 ... D18-1/8 (D460) DC Motor SIC-71FW-D490-1 ... 1 8 850 / 850 90 - Internal Controller Yes Yes - Aluminum Plate Fin / Copper Tube 2 18.1 6.40 (0.595) Acrylic baked-on enamel finish DATA SUBJECT TO CHANGE WITHOUT NOTICE. 13