Sanyo 24KHS72 Service Manual - Page 13

Control PCB, External Finish, Heat Exchanger Coil, Compressor, Fan Motor

Page 13 highlights

Outdoor Unit CH2472 Control PCB Part No. Controls Control Circuit Fuse Compressor Type Compressor Model / Nominal Output Compressor Oil ... Amount Pints (cc) Coil Resistance (Ambient Temp. 68 °F (20 °C)) Ohm Safety Device CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Overload Relay Model Operation Temp. Run Capacitor Micro F VAC Crankcase Heater Fan Type Q'ty ... Dia. inch (mm) Fan Motor Type Model ... Q'ty No. of Poles Rough Measure RPM (Cool / Heat) Nominal Output Coil Resistance (Ambient Temp. 68 °F (20 °C)) Safety Device Type Over- Current Protection Over- Heat Protection Run Capacitor W Ohm Micro F VAC Heat Exchanger Coil Coil Rows Fins per inch Face Area ft2 (m2) External Finish CB-CH2472 Microprocessor 250V 25A DC Twin Rotary (Hermetic) G8T265FU1JW / 2,410W FV50S ... 1.49 (700) U - V : 0.36 V - W : 0.36 W - U : 0.36 Yes Yes Yes CS-7L115 Open : 239 °F (115 °C), Close : 203 °F (95 °C) 230V 30W Propeller 1 ... D18-1/8 (D460) DC Motor SIC-71FW-D490-1 ... 1 8 850 / 850 90 - Internal Controller Yes Yes - Aluminum Plate Fin / Copper Tube 2 18.1 6.40 (0.595) Acrylic baked-on enamel finish DATA SUBJECT TO CHANGE WITHOUT NOTICE. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111

Outdoor Unit
CH2472
Control PCB
Control Circuit Fuse
Controls
Part No.
Microprocessor
250V 25A
CB-CH2472
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Pints (cc)
-
Micro F
VAC
External Finish
Acrylic baked-on enamel finish
FV50S ... 1.49 (700)
-
-
Internal Controller
Yes
Aluminum Plate Fin / Copper Tube
2
18.1
Face Area
ft
2
(m
2
)
6.40 (0.595)
Coil
Rows
Fins per inch
Heat Exchanger Coil
SIC-71FW-D490-1 ... 1
Compressor Oil ...
Amount
8
90
850 / 850
Ohm
DC Motor
Type
Compressor Model / Nominal Output
Compressor
Coil Resistance (Ambient Temp. 68 °F (20 °C))
Ohm
DC Twin Rotary (Hermetic)
G8T265FU1JW / 2,410W
U - V :
V - W :
W - U :
0.36
0.36
0.36
CT (Peak current cut-off control)
Compressor Discharge Temp. Control
Operation cut-off control in abnormal ambient Temp.
Safety Device
Micro F
VAC
Run Capacitor
Crankcase Heater
Yes
Yes
Yes
Overload Relay
CS-7L115
Model
Operation Temp.
Open : 239 °F (115 °C), Close : 203 °F (95 °C)
-
-
230V 30W
1 ... D18-1/8 (D460)
Fan
Propeller
Q'ty ... Dia.
inch (mm)
Type
Type
Over- Current Protection
Yes
Over- Heat Protection
(Ambient Temp. 68 °F (20 °C))
Fan Motor
Nominal Output
Coil Resistance
Safety Device
Rough Measure RPM (Cool / Heat)
Run Capacitor
Type
Model ... Q'ty
No. of Poles
W