Installation Site Selection
View all Sanyo 24KHS72 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 90 highlights
1-5. Additional Materials Required for Installation 1. Refrigeration (armored) tape 2. Insulated staples or clamps for connecting wire (See local codes) 3. Putty 4. Refrigeration lubricant 5. Clamps or saddles to secure refrigerant tubing Indoor unit 2. Installation Site Selection 2-1. Indoor Unit WARNING AVOID: To prevent abnormal heat generation and the possibility of fire, do not place obstacles, enclosures and grilles in front of or surrounding the air conditioner in a way that may block air flow. Drain hose Outside drainage Fig. 1 2" (5 cm) min. 6" (15 cm) min. 2" (5 cm) min. G direct sunlight. Front View G nearby heat sources that may affect performance of the unit. Fig. 2 G areas where leakage of flammable gas may be expected. G places where large amounts of oil mist exist. DO: INDOOR UNIT Tubing length (L) G select an appropriate position from which every corner of the room can be uniformly cooled. (High on a wall is best.) G select a location that will hold the weight of the unit. Elevation difference (H) OUTDOOR UNIT G select a location where tubing and drain hose have the shortest run to the outside. (Fig. 1) Fig. 3a G allow room for operation and maintenance as well as unrestricted air flow around the unit. (Fig. 2) CAUTION Indoor unit G install the unit within the maximum elevation difference (H) For stable operation of the Wall above or below the outdoor unit and within a total tubing length air conditioner, do not (L) from the outdoor unit as detailed in Table 3 and Fig. 3a. install wall-mounted type Minimum height G Install the indoor unit more than 3.3' (1 m) away from any indoor units less than 5' from floor level antenna or power lines or connecting wires used for television, (1.5 m) from floor level. 5' (1.5 m) radio, telephone, security system, or intercom. Electrical noise from any of these sources may affect operation. Floor level Table 3 Fig. 3b Model KHS1872 KHS2472 Max. Allowable Tubing Length at Shipment (ft.) 25 33 Limit of Tubing Length (L) (ft.) 98 98 Limit of Elevation Difference (H) (ft.) 49 49 Required Amount of Additional Refrigerant (oz./ft.)* 0.27 0.27 * If total tubing length becomes 25 to 98 ft. (Max.) or 33 to 98 ft. (Max.), charge additional refrigerant (R410A) by 0.27 oz./ft. No additional charge of compressor oil is necessary. For more detailed charging information, refer to the Technical & Service Manual. 4