Sanyo 24KHS72 Service Manual - Page 27
Heating Capacity
View all Sanyo 24KHS72 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
5-4. Heating Capacity Indoor Unit : KHS1872 Outdoor Unit : CH1872 Power Supply : 230V Single Phase 60Hz < Heating Capacity > RATING CAPACITY: OUTDOOR ENT. TEMP. oF (oC) W.B. 0 (-17.8) 20,400 BTU/h 60 (15.6) TH 11,320 3 (-16.1) TH 11,700 8 (-13.3) TH 12,620 13 (-10.6) TH 13,570 18 (-7.8) TH 14,610 23 (-5.0) TH 15,710 28 (-2.2) TH 16,850 33 (0.6) TH 18,030 38 (3.3) TH 19,200 43 (6.1) TH 20,440 48 (8.9) TH 21,700 53 (11.7) TH 22,970 58 (14.4) TH 24,190 63 (17.2) TH 25,450 65 (18.3) TH 25,930 AIR FLOW RATE: INDOOR AMBIENT TEMP. oF (oC) 65 (18.3) 70 (21.1) 11,320 11,310 11,700 11,690 12,610 12,600 13,560 13,550 14,610 14,590 15,700 15,690 16,840 16,830 18,020 18,000 19,190 19,170 20,430 # 20,400 21,680 21,650 22,940 22,910 24,160 24,120 25,410 25,360 25,900 25,850 541 CFM 75 (23.9) 11,290 11,680 12,590 13,530 14,570 15,660 16,800 17,970 19,130 20,360 21,600 22,860 24,060 25,300 25,780 80 (26.7) 11,270 11,650 12,560 13,510 14,540 15,630 16,760 17,930 19,090 20,310 21,550 22,790 23,990 25,220 25,700 TH : Total Heating Capacity (BTU/h) NOTE 1. Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) D.B. : Outdoor Ambient Temp. 47 °F (8.3 °C) D.B. / 43 °F (6.1 °C) W.B. 2. Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air Prevention Protection during heating operation into account. For this reason, the value may vary from the actual heating characteristics. 3. Above data represents the value when the operation frequency of a compressor is fixed. 27