Sennheiser SL DW HEADMIC SET Instruction manual SpeechLine Digital Wireless PD - Page 192

out DHCP using Fixed IP, Sennheiser Control Cockpit

Page 192 highlights

The CHG 4N charger signed IP. Once a DHCP server is available, however, the IP addresses assigned by the server will be used. Integrating the CHG 4N charger into a network without DHCP using Fixed IP If there is no DHCP server in the network and you are working with fixed IP addresses, please observe the following information. The CHG 4N charger is delivered with automatic IP assignment configured by default. After adding it in the Sennheiser Control Cockpit, you can reconfigure it to Fixed IP. To do so, proceed as described above: „Integrating the CHG 4N charger into a network without DHCP using Auto IP". If you wish to do this, you must temporarily reconfigure the host PC on which the Sennheiser Control Cockpit is installed to automatic IP assignment. If the CHG 4N charger is visible in the Sennheiser Control Cockpit, you can do the IP configuration manually: ▷ Change the IP settings under Device Details -> Network in the Sennheiser Control Cockpit. Connecting a pre-configured CHG 4N charger to the Sennheiser Control Cockpit If mDNS is activated (factory setting), the CHG 4N charger is automatically detected in the network. If the charger has been reconfigured according to one of the procedures described above and mDNS has been deactivated, you can add the charger manually using the Add Device function in the Sennheiser Control Cockpit. To add the charger in the Sennheiser Control Cockpit: ▷ Use the Add Device function in the Sennheiser Control Cockpit and enter the pre-configured IP address. Resetting the CHG 4N charger's network settings To reset the network settings to their factory defaults: ▷ Use a pointed object to press the small reset button for at least one second. The settings will be reset once you release the reset button. The factory settings are restored: • Automatic IP assignment • mDNS is activated 191

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214

The CHG 4N charger
191
signed IP. Once a DHCP server is available, however, the IP
addresses assigned by the server will be used.
Integrating the CHG 4N charger into a network with
-
out DHCP using Fixed IP
If there is no DHCP server in the network and you are working
with fixed IP addresses, please observe the following informa
-
tion.
The CHG 4N charger is delivered with automatic IP assign
-
ment configured by default. After adding it in the
Sennheiser
Control Cockpit
, you can reconfigure it to Fixed IP. To do so,
proceed as described above: „Integrating the CHG 4N charger
into a network without DHCP using Auto IP“.
If you wish to do this, you must temporarily reconfigure the
host PC on which the Sennheiser Control Cockpit is installed
to automatic IP assignment.
If the CHG 4N charger is visible in the
Sennheiser Control
Cockpit
, you can do the IP configuration manually:
Change the IP settings under
Device Details -> Network
in
the
Sennheiser Control Cockpit
.
Connecting a pre-configured CHG 4N charger to the
Sennheiser Control Cockpit
If mDNS is activated (factory setting), the CHG 4N charger is
automatically detected in the network.
If the charger has been reconfigured according to one of the
procedures described above and mDNS has been deactivated,
you can add the charger manually using the
Add Device
func
-
tion in the
Sennheiser Control Cockpit
.
To add the charger in the
Sennheiser Control Cockpit
:
Use the
Add Device
function in the
Sennheiser Control
Cockpit
and enter the pre-configured IP address.
Resetting the CHG 4N charger’s network settings
To reset the network settings to their factory defaults:
Use a pointed object to press the small reset button for at
least one second.
The settings will be reset once you release the reset button.
The factory settings are restored:
• Automatic IP assignment
• mDNS is activated