Sharp 208D AR-208S AR-208D Operation Manual Suite - Page 81
Transfer charger, to its original position.
View all Sharp 208D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
TROUBLESHOOTING AND MAINTENANCE Transfer charger 1 Turn the power switch off. (p.13) 2 Ensure that the bypass tray is open and then open the side cover while pressing the side cover open button. 3 Take the charger cleaner out by holding the tab. Set the charger cleaner onto the right end of the transfer charger, gently slide the cleaner to the left end, and then remove it. Repeat this operation two or three times. Note Slide the charger cleaner from the right end to the left end along the groove of the transfer charger. If the cleaner is stopped on the way, smudges on copies may occur. 4 Return the charger cleaner to its original position. Close the side cover by pressing the round projections near the side cover open button. 5 Turn the power switch on. (p.12) 8 79