Sharp PG-D210U PGD210U Operation Manual - Page 37

Wired Remote Control Terminal Specifications

Page 37 highlights

Wired Remote Control Terminal Specifications 1. Specifications of wired remote control input • 3.5ø minijack • External: ‫ם‬5 V (1 A) • Internal: GND 2. Function and transmission codes No. Control Item (Function) 1 VOLUME UP 2 VOLUME DOWN 3 POWER ON 4 POWER OFF 5 CURSOR UP 6 CURSOR DOWN 7 ADJUST UP 8 ADJUST DOWN 9 MUTE 10 MENU 11 VIDEO 1 12 VIDEO 2 13 RGB1 14 RGB 2 15 ENTER 16 INPUT CHECK 17 BLACK SCREEN System Code Data Code External Code Note: C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 • To operate the MOUSE, L-CLICK and R-CLICK functions 1 0 1 1 00 01 01 0 001 0 1 0 1 1 01 01 01 0 001 0 through the wired remote control input, connect the cable 1 0 1 1 0 0 1 1 0 1 0 1 0 1 0 from the wired remote control (supplied) terminal on the pro- 1 0 1 1 0 0 1 1 0 1 0 0 1 1 0 jector to the remote control. The codes for these functions are 1 0 1 1 00 01 11 0 011 0 1 0 1 1 01 01 11 0 011 0 complex and are, therefore, not listed here. 1 0 1 1 0 1 1 1 1 0 0 1 0 1 0 Wired remote control function code 1 0 1 1 00 00 01 0 101 0 LSB 1 0 1 1 0 1 1 1 0 1 0 0 0 1 0 MSB 1 0 1 1 00 01 00 0 111 0 1 0 1 1 00 10 01 1 001 0 C1 System Code C5 C6 Data Code C13 C14 C15 1 0 1 1 01 10 01 1 001 0 1 0 1 1 0 * * * * * * * * 1 0 1 0 1 1 01 01 01 1 001 0 1 0 1 1 0 0 1 1 0 1 1 0 0 1 0 • System codes C1 to C5 are fixed at "10110". 1 0 1 1 0 1 1 1 0 1 0 1 0 1 0 • Codes C14 and C15 are reverse confirmation bits, with "10" 1 0 1 1 01 10 11 0 001 0 1 0 1 1 0 1 0 0 1 0 1 1 0 1 0 indicating "Front" and "01" indicating "Rear". 3. Sharp remote control signal format 1. Transmission format a. 15-bit format D D D D D D D D D D D D D 67.5 ms 67.5 ms 2. Wave form of output signal • Output using Pulse Position Modulation t T1 T0 "1" "0" "0" "0" 26.4 µs "0" "1" "0" t D • t ‫ ס‬264 µs • To ‫ ס‬1.05 ms • T1 ‫ ס‬2.10 ms • Pulse carrier frequency ‫ ס‬455/12 kHz • Duty ratio ‫ ס‬1:1 3. Transmission control code a. 15 bit b. Example of Reverse D to C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 System Address Function Key Data Bit Data Expansion Mask Data Deter- mination D to D Common Data Bit Reverse in D D C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 1 0 1 1 0 1 0 0 0 0 0 0 0 1 0 D C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 1 0 1 1 0 0 1 1 1 1 1 1 1 0 1 E-36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

E-36
Wired Remote Control Terminal Specifications
1.
Specifications of wired remote control input
• 3.5ø minijack
• External:
5 V (1 A)
• Internal: GND
2.
Function and transmission codes
Wired remote control function code
1
0
1
1
0
*
*
*
*
*
*
*
*
1
0
C1
System Code
C5
C6
Data Code
C13
C14
C15
LSB
MSB
System codes C1 to C5 are fixed at “10110”.
Codes C14 and C15 are reverse confirmation bits, with “10”
indicating “Front” and “01” indicating “Rear”.
Note:
To operate the MOUSE, L-CLICK and R-CLICK functions
through the wired remote control input, connect the cable
from the wired remote control (supplied) terminal on the pro-
jector to the remote control. The codes for these functions are
complex and are, therefore, not listed here.
3.
Sharp remote control signal format
1.
Transmission format
a. 15-bit format
2.
Wave form of output signal
• Output using Pulse Position Modulation
D
D
D
D
D
D
D
D
D
D
D
D
D
67.5 ms
67.5 ms
“0”
“1”
“0”
D
“0”
“0”
“0”
“1”
T
0
T
1
t
• t
4
264 μs
• To
4
1.05 ms
• T1
4
2.10 ms
• Pulse carrier frequency
4
455/12 kHz
• Duty ratio
4
1:1
3.
Transmission control code
a. 15 bit
b. Example of Reverse D to
C1
1
D
C2
0
C3
1
C4
1
C5
0
C6
1
C7
0
C8
0
C9
0
C10
0
C11
0
C12
0
C13
0
C14
1
C15
0
C1
1
D
C2
0
C3
1
C4
1
C5
0
C6
0
C7
1
C8
1
C9
1
C10
1
C11
1
C12
1
C13
1
C14
0
C15
1
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
System Address
D to D Common Data Bit
Reverse in D
Function Key Data Bit
Data
Expansion
Data
Deter-
mination
Mask
C15
VOLUME UP
VOLUME DOWN
POWER ON
POWER OFF
CURSOR UP
CURSOR DOWN
ADJUST UP
ADJUST DOWN
MUTE
MENU
VIDEO 1
VIDEO 2
RGB1
RGB 2
ENTER
INPUT CHECK
BLACK SCREEN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
C1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
C2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
C3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
C4
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
C5
0
1
0
0
0
1
1
0
1
0
0
1
1
0
1
1
1
C6
0
0
1
1
0
0
1
0
1
0
1
1
0
1
1
1
0
C7
1
1
1
1
1
1
1
0
1
1
0
0
1
1
1
0
0
C8
0
0
0
0
1
1
1
0
0
0
0
0
0
0
0
1
1
C9
1
1
1
1
1
1
0
1
1
0
1
1
1
1
1
1
0
C10
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
0
1
C11
0
0
1
0
0
0
1
1
0
1
0
0
0
0
1
0
1
C12
0
0
0
1
1
1
0
0
0
1
0
0
0
0
0
0
0
C13
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
C14
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
C15
No.
Control Item
System Code
Data Code
External Code
(Function)
t
26.4
μ
s