Symptom The power is on, but the camera does not work. Cause • The built-in microcomputer is not working properly. You cannot identify the indicator on the LCD screen. The lens does not move when you turn off the camera. (DSC-P71 only) The lens gets fogged. - • The battery pack is discharged. • Condensation is occurring. Solution p Remove, and then, after one minute, reinstall the battery. If this doesn't work, press the RESET button on the bottom of the camera with pointed object, then turn the power on again. (This will clear the date/time settings, etc.) p Check the indicator (pages 103 to 105). p Replace it with a charged battery or use the AC power adaptor (not supplied) (pages 14, 17, 19). p Leave the camera for about an hour and then try to use it again (page 99). 88