Sony HDCU-4300 Operation Guide - Page 62

ABSENT, FAULT, name, No., Display, Description, OK, PLD ERROR, TEMP

Page 62 highlights

DIAGNOSIS Page name Page No. Item D06 (When HKCU-IP43F is installed) POWER(NET) POWER(CN) NMI1 SFP+ MODULE TX RX NMI2 SFP+ MODULE TX RX D06 (When HKCU-4001 is installed) BOARD S/N IF FAN1 FAN2 NET NET1 NET2 BOARD S/N Display OK, ABSENT OK, FAULT OK, LOS OK, ABSENT OK, FAULT OK, LOS OK, STOP OK, STOP OK, PLD ERROR, TEMP WARNING OK, PLD ERROR, TEMP WARNING Description Displays the SFP+ module status of NMI1. OK: SFP+ module is inserted successfully. ABSENT: SFP+ module is not inserted. OK: Normal FAULT: An error occurred during signal transmission. OK: Normal LOS: Signal could not be received. Displays the SFP+ module status of NM2. OK: SFP+ module is inserted successfully. ABSENT: SFP+ module is not inserted. OK: Normal FAULT: An error occurred during signal transmission. OK: Normal LOS: Signal could not be received. Serial number of the NET board. Displays the FAN1 status of the IF board. Displays the FAN2 status of the IF board. Displays the SFP+ module status of NMI1. Displays the status of the PLD installed on the NET board. Displays the status of the PLD installed on the NET board. Serial number of the HKCU-4001 board. a) DPR(Sub) may not be displayed, depending on the lot number of the board loaded in the unit. If this occurs, there is no effect on functionality. 62

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

62
a)
DPR(Sub) may not be displayed, depending on the lot number of the board loaded in the unit. If this occurs, there is no effect on functionality.
<BOARD STATUS(NMI)>
D06
(When HKCU-IP43F is
installed)
POWER(NET)
POWER(CN)
NMI1 SFP+
Displays the SFP+ module status of NMI1.
MODULE
OK, ABSENT
OK:
SFP+ module is inserted successfully.
ABSENT:
SFP+ module is not inserted.
TX
OK, FAULT
OK:
Normal
FAULT:
An error occurred during signal
transmission.
RX
OK, LOS
OK:
Normal
LOS:
Signal could not be received.
NMI2 SFP+
Displays the SFP+ module status of NM2.
MODULE
OK, ABSENT
OK:
SFP+ module is inserted successfully.
ABSENT:
SFP+ module is not inserted.
TX
OK, FAULT
OK:
Normal
FAULT:
An error occurred during signal
transmission.
RX
OK, LOS
OK:
Normal
LOS:
Signal could not be received.
BOARD S/N
Serial number of the NET board.
<BOARD
STATUS(HKCU-4001)>
D06
(When HKCU-4001 is
installed)
IF
FAN1
OK, STOP
Displays the FAN1 status of the IF board.
FAN2
OK, STOP
Displays the FAN2 status of the IF board.
NET
Displays the SFP+ module status of NMI1.
NET1
OK, PLD ERROR, TEMP
WARNING
Displays the status of the PLD installed on the NET
board.
NET2
OK, PLD ERROR, TEMP
WARNING
Displays the status of the PLD installed on the NET
board.
BOARD S/N
Serial number of the HKCU-4001 board.