TEAC CD-9010 SYSTEM Owners Manual - Page 30

Master clock and digital output combinations, Setting the master word clock, Mono mix setting

Page 30 highlights

7 - Other settings and information display Setting the master word clock You can set the source to use for word synchronization. 1. Press the MENU button to open the MENU screen. 2. Open the SYSTEM menu. 3. Select CLOCK MASTER. Mono mix setting You can set the mono mix output for when the STEREO/MONO button is used to set the output to mono. The setting state is shown to the left of the level meters. 1. Press the MENU button to open the MENU screen. 2. Open the SYSTEM menu. 3. Select MONO MIX. 4. Press the DATA dial to move the cursor right to select the setting. 5. Turn the DATA dial to set the master word clock. •• INT (default value): Use the unit's internal clock •• EXT: Synchronize with the word clock input through the WORD SYNC IN connector •• 44.1K FIX: Regardless of the file sampling frequency, digital audio is always output at 44.1k FS. 6. After completing the setting, press the HOME button to return to the Home Screen. NOTE •• The master clock setting is retained even when the power is turned OFF. •• Depending on the combination of master clock and playback file sampling frequency settings, the digital output sampling frequency will differ. (See "Master clock and digital output combinations" below.) 4. Press the DATA dial to move the cursor right to select the setting. 5. Turn the DATA dial to set the mono mix. -6dB L+R -3dB L+R L Mono R Mono OFF (default value) The left and right channels of the stereo audio track are each attenuated by -6 dB, summed and then output. The left and right channels of the stereo audio track are each attenuated by -3 dB, summed and then output. The left channel of the stereo audio track is output from both L and R outputs. The right channel of the stereo audio track is output from both L and R outputs. The mono mix function is OFF. 6. After completing the setting, press the HOME button to return to the Home Screen. NOTE The mono mix setting is retained even when the power is turned OFF. Master clock and digital output combinations Depending on the combination of the master clock setting and the playback file sampling frequency, the digital output sampling frequency varies. This table shows the combinations. Master clock Internal External (44.1kHz) External (48kHz) Master clock setting Playback file sampling frequency SRC (automatic) Digital output sampling frequency Notes INT 44.1 kHz OFF 44.1 kHz The whole system uses 44.1kHz internal clock 44.1kHz FIX 44.1 kHz OFF 44.1 kHz Digital output is always 44.1 kHz 44.1kHz FIX 48 kHz ON 44.1 kHz Digital output is always 44.1 kHz INT 48 kHz OFF 48 kHz The whole system uses 48kHz internal clock EXT 44.1 kHz OFF 44.1 kHz The whole system uses 44.1kHz external clock EXT 44.1 kHz EXT 48 kHz ON 48 kHz OFF 48 kHz While syncing to 48kHz external clock, the system uses 44.1kHz internal clock The whole system uses 48kHz external clock NOTE •• The sampling rate converter (SRC) function is turned ON and OFF automatically. •• If the clock is interrupted when synchronized with a 48kHz external clock, the unit will switch to internal clock, the sampling rate converter (SRC) function will turn ON and output will continue at 48 kHz. 30 TASCAM CD-9010

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

30
TASCAM CD-9010
7 – Other settings and information display
Setting the master word clock
You can set the source to use for word synchronization.
1.
Press the
MENU
button to open the
MENU
screen.
2.
Open the
SYSTEM
menu.
3.
Select
CLOCK MASTER
.
4.
Press the DATA dial to move the cursor right to select the
setting.
5.
Turn the
DATA
dial to set the master word clock.
INT
(default value): Use the unit's internal clock
EXT
: Synchronize with the word clock input through the
WORD SYNC IN
connector
44.1K FIX
: Regardless of the file sampling frequency,
digital audio is always output at 44.1k FS.
6.
After completing the setting, press the
HOME
button to
return to the Home Screen.
NOTE
The master clock setting is retained even when the power is
turned OFF.
Depending on the combination of master clock and
playback file sampling frequency settings, the digital output
sampling frequency will differ. (See "Master clock and digital
output combinations" below.)
Mono mix setting
You can set the mono mix output for when the
STEREO/MONO
button is used to set the output to mono. The setting state is
shown to the left of the level meters.
1.
Press the
MENU
button to open the
MENU
screen.
2.
Open the
SYSTEM
menu.
3.
Select
MONO MIX
.
4.
Press the DATA dial to move the cursor right to select the
setting.
5.
Turn the
DATA
dial to set the mono mix.
–6dB L+R 
The left and right channels of the stereo
audio track are each attenuated by –6 dB,
summed and then output.
–3dB L+R
The left and right channels of the stereo
audio track are each attenuated by –3 dB,
summed and then output.
L Mono
The left channel of the stereo audio track is
output from both L and R outputs.
R Mono
The right channel of the stereo audio track
is output from both L and R outputs.
OFF 
(default
value)
The mono mix function is OFF.
6.
After completing the setting, press the
HOME
button to
return to the Home Screen.
NOTE
The mono mix setting is retained even when the power is turned
OFF.
Master clock and digital output combinations
Depending on the combination of the master clock setting and the playback file sampling frequency, the digital output sampling
frequency varies. This table shows the combinations.
Master
clock
Master clock
setting
Playback file
sampling frequency
SRC
(automatic)
Digital output
sampling frequency
Notes
Internal
INT
44.1 kHz
OFF
44.1 kHz
The whole system uses 44.1kHz internal clock
44.1kHz FIX
44.1 kHz
OFF
44.1 kHz
Digital output is always 44.1 kHz
44.1kHz FIX
48 kHz
ON
44.1 kHz
Digital output is always 44.1 kHz
INT
48 kHz
OFF
48 kHz
The whole system uses 48kHz internal clock
External
(44.1kHz)
EXT
44.1 kHz
OFF
44.1 kHz
The whole system uses 44.1kHz external clock
External
(48kHz)
EXT
44.1 kHz
ON
48 kHz
While syncing to 48kHz external clock, the
system uses 44.1kHz internal clock
EXT
48 kHz
OFF
48 kHz
The whole system uses 48kHz external clock
NOTE
The sampling rate converter (SRC) function is turned ON and OFF automatically.
If the clock is interrupted when synchronized with a 48kHz external clock, the unit will switch to internal clock, the sampling rate
converter (SRC) function will turn ON and output will continue at 48 kHz.