Yamaha CDR-HD1300 Owner's Manual - Page 32

How many, Period, Total, Setting a condition at synchronized record

Page 32 highlights

RECORDING FROM AN EXTERNAL COMPONENT ONTO THE HDD 3. Press the MULTI JOG knob (ENTER on the remote control) to confirm the recording mode selected. If "Manual", "Track Synchro" or "All Synchro" is confirmed, this unit returns the recording pause mode. If "Multi Synchro" is confirmed, following message appears on the display. Make a setting following steps 4 and 5. H o w m a n y ? 1 REC MULT SYNC L dB -30 -10 -6 -2 0 R If "Auto Period" is confirmed, following message appears on the display. Make a setting following steps 6 to 9. P e r i o d ? 3 0 0 REC AUTO PRD L dB -30 -10 -6 -2 0 R TIME 4. Select the number of tracks by rotating the MULTI JOG knob (pressing +/- on the remote control). The number can be set in the 1 to 99 tracks range. 5. Press the MULTI JOG knob (ENTER on the remote control) to confirm the number of tracks to be set. This unit returns to the recording pause mode. 6. Select the time length between track markers by rotating the MULTI JOG knob (pressing +/- on the remote control). The time length can be set in the 10 seconds to 30 minutes range by 10-seconds steps. 7. Press the MULTI JOG knob (ENTER on the remote control) to confirm the time length between the selected track markers. The following message appears on the display. The total recording time can be set. T o t a l ? 0 h 4 m REC AUTO PRD L dB -30 -10 -6 -2 0 R TIME I Setting a condition at synchronized recording This unit automatically detects track intervals when recording is made in track-synchronized recording mode, multi-synchronized recording mode, or all-synchronized recording mode. You can set the condition for detecting track intervals. Setting items are as follows: OPT TH Level Sets the signal level that judges the signals input through the DIGITAL IN (OPTICAL) jack as "no signal". Initial setting: -50dB, Control range: -90 to -20dB COAX TH Level Sets the signal level that judges the signals input through the DIGITAL IN (COAXIAL) jack as "no signal". Initial setting: -50dB, Control range: -90 to -20dB ANLG TH Level Sets the signal level that judges the signals input through the ANALOG LINE IN (REC) jacks as "no signal". Initial setting: -40dB, Control range: -60 to -20dB Int. Time Sets the length of silence ("no signal") that judges track intervals. When the set amount of silence continues, this unit judges it as a track interval and places a track marker. Initial setting: 2.0 seconds, Control range: 0.5 to 5.0 seconds End Duration Sets the length of silence ("no signal") that judges the end of playback when recording in the all-synchronized recording mode. When the set amount of silence continues, recording will be stopped. Initial setting: 12.0 seconds, Control range: 2.0 to 60.0 seconds Note • Settings for "Int. Time" and "End Duration" apply to each input jack. See next page for the setting procedure. 8. Select the total recording time by rotating the MULTI JOG knob (pressing +/- on the remote control). 9. Press the MULTI JOG knob (ENTER on the remote control) to confirm the total recording time. This unit returns to the recording pause mode. Notes • When recording to the HDD in the auto period recording mode, the recording will be performed continuously to the next available disc if the time length between selected track markers exceeds the group remaining time. • In the auto period recording mode, a time error can occur in a frame unit. Therefore, the time of each track or the group total time may not match the confirmed time length between selected track markers or the total recording time. E-26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106

E-
26
RECORDING FROM AN EXTERNAL COMPONENT ONTO THE HDD
3.
Press the MULTI JOG knob (ENTER on the remote
control) to confirm the recording mode selected.
If
Manual
,
Track Synchro
or
All Synchro
is confirmed,
this unit returns the recording pause mode.
If
Multi Synchro
is confirmed, following message appears on
the display. Make a setting following steps 4 and 5.
If
Auto Period
is confirmed, following message appears on
the display. Make a setting following steps 6 to 9.
4.
Select the number of tracks by rotating the MULTI
JOG knob (pressing +/
on the remote control).
The number can be set in the 1 to 99 tracks range.
5.
Press the MULTI JOG knob (ENTER on the remote
control) to confirm the number of tracks to be set.
This unit returns to the recording pause mode.
6.
Select the time length between track markers by
rotating the MULTI JOG knob (pressing +/
on the
remote control).
The time length can be set in the 10 seconds to 30 minutes
range by 10-seconds steps.
7.
Press the MULTI JOG knob (ENTER on the remote
control) to confirm the time length between the
selected track markers.
The following message appears on the display. The total
recording time can be set.
8.
Select the total recording time by rotating the MULTI
JOG knob (pressing +/
on the remote control).
9.
Press the MULTI JOG knob (ENTER on the remote
control) to confirm the total recording time.
This unit returns to the recording pause mode.
Notes
When recording to the HDD in the auto period recording mode,
the recording will be performed continuously to the next available
disc if the time length between selected track markers exceeds the
group remaining time.
In the auto period recording mode, a time error can occur in a
frame unit. Therefore, the time of each track or the group total
time may not match the confirmed time length between selected
track markers or the total recording time.
How many
?
1
REC
L
R
dB
30
10
6
2
0
MULT
SYNC
Period
?
300
AUTO PRD
REC
TIME
L
R
dB
30
10
6
2
0
Total
?
0h 4m
AUTO PRD
REC
TIME
L
R
dB
30
10
6
2
0
Setting a condition at synchronized record-
ing
This unit automatically detects track intervals when recording is
made in track-synchronized recording mode, multi-synchronized
recording mode, or all-synchronized recording mode. You can set
the condition for detecting track intervals. Setting items are as
follows:
OPT TH Level
Sets the signal level that judges the signals input through the
DIGITAL IN
(OPTICAL)
jack as
no signal
.
Initial setting:
50dB, Control range:
90 to
20dB
COAX TH Level
Sets the signal level that judges the signals input through the
DIGITAL IN
(COAXIAL)
jack as
no signal
.
Initial setting:
50dB, Control range:
90 to
20dB
ANLG TH Level
Sets the signal level that judges the signals input through the
ANALOG LINE IN (REC)
jacks as
no signal
.
Initial setting:
40dB, Control range:
60 to
20dB
Int. Time
Sets the length of silence (
no signal
) that judges track intervals.
When the set amount of silence continues, this unit judges it as a
track interval and places a track marker.
Initial setting: 2.0 seconds, Control range: 0.5 to 5.0 seconds
End Duration
Sets the length of silence (
no signal
) that judges the end of
playback when recording in the all-synchronized recording mode.
When the set amount of silence continues, recording will be
stopped.
Initial setting: 12.0 seconds, Control range: 2.0 to 60.0 seconds
Note
Settings for
Int. Time
and
End Duration
apply to each input
jack.
See next page for the setting procedure.