Adaptec 3405 User Guide - Page 117

Update, C:\UFI_FILES

Page 117 highlights

Appendix E: Using the Adaptec Flash Utility ● 117 These switches are available: ● /C -One or more RAID controller IDs representing the set of RAID controllers on which to perform the specified command. The default is 0; if the computer has multiple RAID controllers, the AFU defaults to controller 0 unless you specify otherwise. For example: To specify a single RAID controller ID: /C 0 To specify multiple IDs separated by commas: /C 0,2 To indicate all RAID controllers: ALL If you are using multiple RAID controllers, you must specify the controller you want by using the /C switch; otherwise, the AFU displays an error message and exits. ● /D -Specifies the path where the UFI files are located. If you do not specify the /D switch, the AFU looks for (or creates) its UFI files in the default location. You cannot specify the name of a UFI file, only its path. UFI filenames are predefined, based on the RAID controller type. In this example, the AFU saves flash contents from RAID controller 0 to a UFI file in the current default drive and directory: A:\> AFU SAVE /C 0 In this example, the AFU saves flash contents from Controller 1 to a UFI file in C:\UFI_FILES: A:\> AFU SAVE /C 1 /D C:\UFI_FILES Update Updates the flash components of one or more RAID controllers on your computer from the flash image data in a UFI file. You must restart the computer following an UPDATE command. The command syntax for the UPDATE command is: AFU UPDATE [/C] [/D ] This example shows a typical system response after an update. A:\> AFU UPDATE /C 0 Adaptec Flash Utility V4.0-0 B5749 (c)Adaptec Inc. 1999-2005. All Rights Reserved. Updating Controller 0 (Adaptec RAID 31205) Reading flash image file (Build 5749) AFU is about to update firmware on controllers Adaptec RAID 31205 ***PLEASE DO NOT REBOOT THE SYSTEM DURING THE UPDATE*** This might take a few minutes. Writing Adaptec RAID 31205 (4MB) Flash Image to controller 0...OK. Verifying...OK Please restart the computer to allow firmware changes to take effect.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158

Appendix E: Using the Adaptec Flash Utility
117
These switches are available:
/C <Controller ID>
—One or more RAID controller IDs representing the set of RAID
controllers on which to perform the specified command. The default is 0; if the computer
has multiple RAID controllers, the AFU defaults to controller 0 unless you specify
otherwise.
For example:
To specify a single RAID controller ID:
/C 0
To specify multiple IDs separated by commas:
/C 0,2
To indicate all RAID controllers:
ALL
If you are using multiple RAID controllers, you must specify the controller you want by
using the /C switch; otherwise, the AFU displays an error message and exits.
/D <UFI File Path>
—Specifies the path where the UFI files are located. If you do not
specify the /D switch, the AFU looks for (or creates) its UFI files in the default location.
You cannot specify the name of a UFI file, only its path. UFI filenames are predefined,
based on the RAID controller type.
In this example, the AFU saves flash contents from RAID controller 0 to a UFI file in the
current default drive and directory:
A:\> AFU SAVE /C 0
In this example, the AFU saves flash contents from Controller 1 to a UFI file in
C:\UFI_FILES:
A:\> AFU SAVE /C 1 /D C:\UFI_FILES
Update
Updates the flash components of one or more RAID controllers on your computer from the
flash image data in a UFI file. You must restart the computer following an UPDATE command.
The command syntax for the UPDATE command is:
AFU UPDATE [/C<Controller ID>] [/D <UFI File Path>]
This example shows a typical system response after an update.
A:\> AFU UPDATE /C 0
Adaptec Flash Utility V4.0-0 B5749
(c)Adaptec Inc. 1999–2005. All Rights Reserved.
Updating Controller 0 (Adaptec RAID 31205)
Reading flash image file (Build 5749)
AFU is about to update firmware on controllers Adaptec RAID 31205
***PLEASE DO NOT REBOOT THE SYSTEM DURING THE UPDATE***
This might take a few minutes.
Writing Adaptec RAID 31205 (4MB) Flash Image to controller 0...OK.
Verifying...OK
Please restart the computer to allow firmware changes to take effect.