Adaptec 3405 User Guide - Page 152

Environmental Specifications, DC Power Requirements, Current Requirements

Page 152 highlights

Appendix H: Technical Specifications ● 152 Environmental Specifications Note: Adaptec RAID controllers require adequate airflow to operate reliably. The recommended airflow is 200 LFM. Forced airflow is recommended. Ambient temperature with forced airflow Ambient temperature without forced airflow Ambient temperature with Battery Backup Unit (BBU) Relative humidity Altitude 0 °C to 55 ° C 0 °C to 40 ° C 0 °C to 40 ° C 10% to 90%, noncondensing Up to 3,000 meters Note: Ambient temperature measured 1" from RAID processor. DC Power Requirements Bus Type PCIe PCIe Description Ripple and noise DC Voltage Requirements 50 mV peak-to-peak (max) 3.3 V ± 9%, 12 V ± 8% Current Requirements Adaptec Model Adaptec RAID 5085 Adaptec RAID 5805/5805Q Adaptec RAID 5405 Adaptec RAID 5445 Adaptec RAID 5805Z/5805ZQ Adaptec RAID 5405Z Adaptec RAID 5445Z Adaptec RAID 51245 Adaptec RAID 51645 Adaptec RAID 52445 Adaptec RAID 3085 Adaptec RAID 3405 Adaptec RAID 3805 Adaptec RAID 31205 Adaptec RAID 31605 Adaptec RAID 2045 Adaptec RAID 2405/2405Q Adaptec RAID 2805 Typical Current 0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC 0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC 0.45A @ 3.3VDC; 0.94A @ 12.0VDC 0.45A @ 3.3VDC; 1.0A @ 12.0VDC 0.39 A @ 3.3 VDC; 1.21 A @ 12.0 VDC 0.38 A @ 3.3 VDC; 1.18 A @ 12.0 VDC 0.40 A @ 3.3 VDC; 1.24 A @ 12.0 VDC 0.47A @ 3.3VDC; 1.68A @ 12.0VDC 0.47A @ 3.3VDC; 1.72A @ 12.0VDC 0.47A @ 3.3VDC; 1.78A @ 12.0VDC 1.04 A @ 3.3 VDC; 0.98 A @ 12.0 VDC 1.0 A @ 3.3 VDC; 1.0 A @ 12.0 VDC 1.0 A @ 3.3 VDC; 1.0 A @ 12.0 VDC 1.05 A @ 3.3 VDC; 1.48 A @ 12.0 VDC 1.05 A @ 3.3 VDC; 1.48 A @ 12.0 VDC 0.43A @ 3.3VDC; 0.83A @ 12.0VDC 0.43A @ 3.3VDC; 0.83A @ 12.0VDC 0.5A @ 3.3VDC; 0.95A @ 12.0VDC

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158

Appendix H: Technical Specifications
152
Environmental Specifications
Note:
Adaptec RAID controllers require adequate airflow to operate reliably. The recommended
airflow is 200 LFM. Forced airflow is recommended.
Note:
Ambient temperature measured 1” from RAID processor.
DC Power Requirements
Current Requirements
Ambient temperature with forced airflow
0 °C to 55 °
C
Ambient temperature without forced airflow
0 °C to 40 °
C
Ambient temperature with Battery Backup Unit (BBU)
0 °C to 40 °
C
Relative humidity
10% to 90%
,
noncondensing
Altitude
Up to 3,000 meters
Bus Type
Description
Requirements
PCIe
Ripple and noise
50 mV peak-to-peak (max)
PCIe
DC Voltage
3.3 V ± 9%, 12 V ± 8%
Adaptec Model
Typical Current
Adaptec RAID 5085
0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC
Adaptec RAID 5805/5805Q
0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC
Adaptec RAID 5405
0.45A @ 3.3VDC; 0.94A @ 12.0VDC
Adaptec RAID 5445
0.45A @ 3.3VDC; 1.0A @ 12.0VDC
Adaptec RAID 5805Z/5805ZQ
0.39 A @ 3.3 VDC; 1.21 A @ 12.0 VDC
Adaptec RAID 5405Z
0.38 A @ 3.3 VDC; 1.18 A @ 12.0 VDC
Adaptec RAID 5445Z
0.40 A @ 3.3 VDC; 1.24 A @ 12.0 VDC
Adaptec RAID 51245
0.47A @ 3.3VDC; 1.68A @ 12.0VDC
Adaptec RAID 51645
0.47A @ 3.3VDC; 1.72A @ 12.0VDC
Adaptec RAID 52445
0.47A @ 3.3VDC; 1.78A @ 12.0VDC
Adaptec RAID 3085
1.04 A @ 3.3 VDC; 0.98 A @ 12.0 VDC
Adaptec RAID 3405
1.0 A @ 3.3 VDC; 1.0 A @ 12.0 VDC
Adaptec RAID 3805
1.0 A @ 3.3 VDC; 1.0 A @ 12.0 VDC
Adaptec RAID 31205
1.05 A @ 3.3 VDC; 1.48 A @ 12.0 VDC
Adaptec RAID 31605
1.05 A @ 3.3 VDC; 1.48 A @ 12.0 VDC
Adaptec RAID 2045
0.43A @ 3.3VDC; 0.83A @ 12.0VDC
Adaptec RAID 2405/2405Q
0.43A @ 3.3VDC; 0.83A @ 12.0VDC
Adaptec RAID 2805
0.5A @ 3.3VDC; 0.95A @ 12.0VDC