Adaptec 3405 User Guide - Page 84

RAID 1 Arrays, RAID 1 Enhanced Arrays, A RAID 1 Enhanced RAID 1E array-also known as

Page 84 highlights

Appendix B: Understanding RAID ● 84 RAID 1 Arrays A RAID 1 array is built from two disk drives, where one disk drive is a mirror of the other (the same data is stored on each disk drive). Compared to independent disk drives, RAID 1 arrays provide improved performance, with twice the read rate and an equal write rate of single disks. However, capacity is only 50 percent of independent disk drives. If the RAID 1 array is built from different- sized disk drives, the free space, drive segment size is the size of the smaller disk drive, as shown in this figure. Drive Segment Size (Smallest Disk Drive) Disk Drive 1 250 GB Disk Drive 2 400 GB Disk Drives in Logical Drive Disk Drive 1 1 - 250 Disk Drive 2 1 - 250 Unused Space = 150 GB RAID 1 Logical Drive = 250 GB RAID 1 Enhanced Arrays A RAID 1 Enhanced (RAID 1E) array-also known as a striped mirror-is similar to a RAID 1 array except that data is both mirrored and striped, and more disk drives can be included. A RAID 1E array can be built from three or more disk drives. In this example, the large bold numbers represent the striped data, and the smaller, non-bold numbers represent the mirrored data stripes. Disk Drive 1 400 GB Disk Drive 2 400 GB Disk Drive 3 400 GB Disk Drives in Logical Drive Disk Drive 1 1 3 4 6 Disk Drive 2 2 1 5 4 Disk Drive 3 3 2 6 5 RAID 1E Logical Drive = 600 GB

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158

Appendix B: Understanding RAID
84
RAID 1 Arrays
A RAID 1 array is built from two disk drives, where one disk drive is a
mirror
of the other (the
same data is stored on each disk drive). Compared to independent disk drives, RAID 1 arrays
provide improved performance, with twice the read rate and an equal write rate of single disks.
However, capacity is only 50 percent of independent disk drives.
If the RAID 1 array is built from different- sized disk drives, the free space, drive segment size is
the size of the smaller disk drive, as shown in this figure.
RAID 1 Enhanced Arrays
A RAID 1 Enhanced (RAID 1E) array—also known as a
striped mirror
—is similar to a RAID 1
array except that data is both mirrored
and
striped, and more disk drives can be included. A
RAID 1E array can be built from three or more disk drives.
In this example, the large bold numbers represent the striped data, and the smaller, non-bold
numbers represent the mirrored data stripes.
Disk Drive 2
Disk Drive 1
250 GB
400 GB
Drive Segment Size
(Smallest Disk Drive)
Disk Drive 1
Disk Drive 2
Disk Drives in Logical Drive
RAID 1 Logical Drive = 250 GB
1 – 250
1 – 250
Unused Space = 150 GB
Disk Drive 2
Disk Drive 1
400 GB
Disk Drives in Logical Drive
RAID 1E Logical Drive = 600 GB
400 GB
400 GB
Disk Drive 3
Disk Drive 2
Disk Drive 1
Disk Drive 3
1
3
2
3
4
5
6
1
2
6
4
5