Brother International BAS-342E Instruction Manual - English - Page 58

Brother International BAS-342E Manual

Page 58 highlights

12. Error codes ■ Error codes[E.9 * [E.F * ] A DANGER A Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet before opening the face plate of the control box. Touching areas where high voltages are present can result in severe injury. Code Cause Remedy E.90 Abnormal drop in power supply voltage, or power was Turn off the power and check the input voltage. turned on again immediately after it was turned off. After turning off the power, wait 3 seconds or more before turning it on again. . . E.91 Abnormal rise in power supply voltage. Turn off the power and check the input voltage. E.A0 Starting switch was pressed without any valid sewing data loaded. Re-read the sewing data. E.A1 Home position point was not detected within a Turn off the power and check the X-Y feed and the certain time during home position detection. home position sensor connection. E.c0 Motor PROM is not correctly inserted. . . Turn off the power and check. E.c1 The box cooling fan (at the left when looking from Turn off the power and check whether any thread scraps the front) is not operating. have built up. E.c2 Heat sink of control circuit board is abnormally hot. Turn off the power and clean the air intake port of the box. . . E.c3 Abnormal current detected in X pulse motor. Turn off the power and contact a qualified service technician. . . E.c4 Abnormal current detected in X pulse motor. Turn off the power and contact a qualified service technician. . . E.c5 The box cooling fan (at the right when looking from Turn off the power and check whether any thread the front) is not operating. scraps have built up. E.d0 Air pressure drop error. Turn off the power and check. E.E0 Main PROM is not correctly inserted. . . Turn off the power and check. E.E1 Communication error detected by control circuit board. Turn off the power, wait a while and then turn it back on. . . E.E2 Communication error detected by panel circuit board. Turn off the power, wait a while and then turn it back on. . . E.E3 Bad connection in cable between panel and box. Turn off the power and check. E. F0 Power relay is not operating (malfunction of power supply circuit board). Turn off the power and contact a qualified service technician. - ' E.F1 Bad connection in cable between power supply circuit board and main circuit board. . . Turn off the power and check. E.F2 Abnormal current detected in power supply circuit board. Turn off the power and contact a qualified service technician. REFERENCE' segment LED alphabet tLIi R b cdEF Panel display ISH L. 0 Text display A b c d E F 6 H L O BAS-341E • 342E 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

12.
Error
codes
Error
codes[E.9
*
[E.F
*
]
A
DANGER
A
Wait
at
least
5
minutes
after
turning
off
the
power
switch
and
disconnecting
the
power
cord
from
the
wall
outlet
before
opening
the
face
plate
of
the
control
box.
Touching
areas
where
high
voltages
are
present
can
result
in
severe
injury.
Code
Cause
Remedy
E.90
.
E.91
Abnormal
drop
in
power
supply
voltage,
or
power
was
turned
on
again
immediately
after
it
was
turned
off.
Abnormal
rise
in
power
supply
voltage.
Turn
off
the
power
and
check
the
input
voltage.
After
turning
off
the
power,
wait
3
seconds
or
more
before
turning
it
on
again.
.
Turn
off
the
power
and
check
the
input
voltage.
E.A0
E.A1
Starting
switch
was
pressed
without
any
valid
sewing
data
loaded.
Home
position
point
was
not
detected
within
a
certain
time
during
home
position
detection.
Re
-read
the
sewing
data.
Turn
off
the
power
and
check
the
X
-Y
feed
and
the
home
position
sensor
connection.
E.c0
.
E.c1
E.c2
.
E.c3
.
E.c4
.
E.c5
Motor
PROM
is
not
correctly
inserted.
The
box
cooling
fan
(at
the
left
when
looking
from
the
front)
is
not
operating.
Heat
sink
of
control
circuit
board
is
abnormally
hot.
Abnormal
current
detected
in
X
pulse
motor.
Abnormal
current
detected
in
X
pulse
motor.
The
box
cooling
fan
(at
the
right
when
looking
from
the
front)
is
not
operating.
Turn
off
the
power
and
check.
.
Turn
off
the
power
and
check
whether
any
thread
scraps
have
built
up.
Turn
off
the
power
and
clean
the
air
intake
port
of
the
box.
.
Turn
off
the
power
and
contact
a
qualified
service
technician.
.
Turn
off
the
power
and
contact
a
qualified
service
technician.
.
Turn
off
the
power
and
check
whether
any
thread
scraps
have
built
up.
E.d0
Air
pressure
drop
error.
Turn
off
the
power
and
check.
E.E0
.
E.E1
.
E.E2
.
E.E3
Main
PROM
is
not
correctly
inserted.
Communication
error
detected
by
control
circuit
board.
Communication
error
detected
by
panel
circuit
board.
Bad
connection
in
cable
between
panel
and
box.
Turn
off
the
power
and
check.
.
Turn
off
the
power,
wait
a
while
and
then
turn
it
back
on.
.
Turn
off
the
power,
wait
a
while
and
then
turn
it
back
on.
.
Turn
off
the
power
and
check.
E.
F0
-
E.F1
.
E.F2
Power
relay
is
not
operating
(malfunction
of
power
supply
circuit
board).
Bad
connection
in
cable
between
power
supply
circuit
board
and
main
circuit
board.
Abnormal
current
detected
in
power
supply
circuit
board.
Turn
off
the
power
and
contact
a
qualified
service
technician.
'
Turn
off
the
power
and
check.
.
Turn
off
the
power
and
contact
a
qualified
service
technician.
REFERENCE'
segment
LED
alphabet
Panel
display
R
b
cdEF
ISH
L.
0
LI
t
i
Text
display
A
b
c
d
E
F
6
H
L
O
BAS
-341
E
342E
51