Brother International PR-1000 Operation Manual - Page 288
Using the included cleaning brush, remove
View all Brother International PR-1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 288 highlights
APPENDIX ■ Disassembling and cleaning the tension unit To remove tension dial, turn dial 1 counterclockwise as shown on illustration. 1 Tension dial Using the included cleaning brush, remove 2 any lint and dust from the two pieces of felt washers (top, bottom) inside the tension dial. Reassembling the tension unit. 3 Note ● When reassembling the tension unit, be sure not to install the tension disc upsidedown. There is a magnet on the bottom. Bottom Top 1 Magnet ● When reassembling the tension unit, be careful not to lose any parts or install any parts in an incorrect order. The machine may not operate correctly if the tension units are incorrectly reassembled. 1 Tension dial 2 Nylon shoulder washer 3 Tension spring 4 Tension base spring 5 Felt washer (top) 6 Tension disc 7 Felt washer (bottom) 286