Canon PowerShot G5 Service Manual - Page 65
Assembling the FINDER UNIT
View all Canon PowerShot G5 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
Hole Cutout CHAPTER 3. REPAIR INSTRUCTION (1)-2 A Rotate the gear in the direction of mark A as far as it can go. When it reaches its end, return it slightly so that cutouts are aligned with the two holes of the gear. FINDER UNIT q (1)-6 (1)-4 Claw B (1)-5 Dowel LED HOLDER (1)-3 C (1)-1 OPTICAL UNIT/ LED HOLDER NOTE (Assembling) (1)-1 Fig. 3-17 Assembling the FINDER UNIT q XA4-9170-359 3.5mm BLACK M1.7 (SELF TAP) 2.2.14 Assembling the FINDER UNIT (1) FINDER UNIT 1. Set the OPTICAL UNIT in the retracted position. 2. Rotated the gear in the direction of mark A as far as it can go. When it reaches its end, return it slightly so that cutouts are aligned with the two holes of the gear. 3. Insert the LED HOLDER to the FINDER UNIT. 4. Install the claw. 5. Install the dowel in the opposite side. 6. Install the two screws of q. NOTE (Assembling) If the OPTICAL UNIT is not set in the retracted position, remove the CCD HOLDER UNIT (refer to page 3-28) and rotate the portion B of the OPTICAL UNIT in the direction of mark C with hands until the OPTICAL UNIT is set in the retracted position. 3-17