Cisco 3750G-12S Hardware Installation Guide - Page 126

C-10, Inserting the Terminal Block in the Block Header, Step 9, Caution

Page 126 highlights

Connecting to DC Power Appendix C Connecting to DC Power Figure C-10 Inserting the Terminal Block in the Block Header 132636 STACK 1 STACK 2 CONSOLE 336.0--712.V5A B- + A- + 2 1 1 Tie wrap 2 Terminal block Step 9 Remove the tape from the circuit-breaker switch handle, and move the circuit-breaker handle to the on position. Caution To comply with the intrabuilding lightning surge requirements, intrabuilding wiring must be shielded, and the shield for the wiring must be grounded at both ends. Caution The Catalyst 3750G-12S-SD switch is suitable only for intrabuilding or nonexposed wiring connections. Catalyst 3750 Switch Hardware Installation Guide C-8 OL-6336-10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146

C-8
Catalyst 3750 Switch Hardware Installation Guide
OL-6336-10
Appendix C
Connecting to DC Power
Connecting to DC Power
Figure C-10
Inserting the Terminal Block in the Block Header
Step 9
Remove the tape from the circuit-breaker switch handle, and move the circuit-breaker handle to the
on position.
Caution
To comply with the intrabuilding lightning surge requirements, intrabuilding wiring must be shielded,
and the shield for the wiring must be grounded at both ends.
Caution
The Catalyst 3750G-12S-SD switch is suitable only for intrabuilding or nonexposed wiring connections.
1
Tie wrap
2
Terminal block
CONSOLE
STACK 1
STACK 2
2
1
132636
36 - 72V
3.0 - 1.5A
A
+
B
+