Cisco 3750G-12S Hardware Installation Guide - Page 99

Table A-3, Specifications for the Catalyst 3750-24FS Switch, Dimensions H x W x D - s dimensions

Page 99 highlights

Appendix A Technical Specifications Table A-3 Specifications for the Catalyst 3750-24FS Switch Environmental Ranges Operating temperature 32 to 113°F (0 to 45°C) Storage temperature -13 to 158°F (-25 to 70°C) Relative humidity 10 to 85% (noncondensing) Operating altitude Up to 10,000 ft (3049 m) Storage altitude Up to 15,000 ft (4573 m) Power Requirements AC input voltage 100 to 240 VAC (autoranging) 1.5 to 3 A, 50 to 60 Hz DC input voltages for RPS 2300 and 675 +12 V @8.5 A Power consumption 70 W, 240 BTUs per hour Power rating 0.070 kVA Physical Dimensions Weight 9 lb (4.1 kg) Dimensions (H x W x D) 1.73 x 17.5 x 11.8 in. (4.4 x 44.5 x 30.1 cm) Table A-4 Specifications for the Catalyst 3750-24TS Switch Environmental Ranges Operating temperature 32 to 113°F (0 to 45°C) Storage temperature -13 to 158°F (-25 to 70°C) Relative humidity 10 to 85% (noncondensing) Operating altitude Up to 10,000 ft (3049 m) Storage altitude Up to 15,000 ft (4573 m) Power Requirements AC input voltage 100 to 240 VAC (autoranging) 0.6 to 1.2 A, 50 to 60 Hz DC input voltages for RPS 2300 and 675 +12 V @8.5 A Power consumption 50 W, 171 BTUs per hour Power rating 0.083 kVA Physical Dimensions Weight 8 lb (3.6 kg) Dimensions (H x W x D) 1.73 x 17.5 x 11.8 in. (4.4 x 44.5 x 30.1 cm) OL-6336-10 Catalyst 3750 Switch Hardware Installation Guide A-3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146

A-3
Catalyst 3750 Switch Hardware Installation Guide
OL-6336-10
Appendix A
Technical Specifications
Table A-3
Specifications for the Catalyst 3750-24FS Switch
Environmental Ranges
Operating temperature
32 to 113°F (0 to 45°C)
Storage temperature
–13 to 158°F (–25 to 70°C)
Relative humidity
10 to 85% (noncondensing)
Operating altitude
Up to 10,000 ft (3049 m)
Storage altitude
Up to 15,000 ft (4573 m)
Power Requirements
AC input voltage
100 to 240 VAC (autoranging)
1.5 to 3 A, 50 to 60 Hz
DC input voltages for
RPS 2300 and 675
+12 V
@8.5 A
Power consumption
70 W, 240 BTUs per hour
Power rating
0.070 kVA
Physical Dimensions
Weight
9 lb (4.1 kg)
Dimensions (H x W x D)
1.73 x 17.5 x 11.8 in. (4.4 x 44.5 x 30.1 cm)
Table A-4
Specifications for the Catalyst 3750-24TS Switch
Environmental Ranges
Operating temperature
32 to 113°F (0 to 45°C)
Storage temperature
–13 to 158°F (–25 to 70°C)
Relative humidity
10 to 85% (noncondensing)
Operating altitude
Up to 10,000 ft (3049 m)
Storage altitude
Up to 15,000 ft (4573 m)
Power Requirements
AC input voltage
100 to 240 VAC (autoranging)
0.6 to 1.2 A, 50 to 60 Hz
DC input voltages for
RPS 2300 and 675
+12 V
@8.5 A
Power consumption
50 W, 171 BTUs per hour
Power rating
0.083 kVA
Physical Dimensions
Weight
8 lb (3.6 kg)
Dimensions (H x W x D)
1.73 x 17.5 x 11.8 in. (4.4 x 44.5 x 30.1 cm)