Danby DPAC8399 User Guide - Page 22

How the External Water Tank, Feature Works

Page 22 highlights

Remote Control Operating Instructions (cont'd) How the External Water Tank Feature Works 6. Swing Setting: Press the remote "Swing" button to activate the automatic air swing (oscillation) feature. The symbol " " will momentarily appear in the LCD window confirming the "swing" feature is activated and/or deactivated. 7. L(Lock) Button: Press the remote "L" button to guard against accidental program change. When the "L" button is depressed, the lock symbol ( ) will be displayed in the remote LCD window. Press the "L" button again to unlock the registered program (key symbol will disappear). 8. R (Re-set) Button: Press the remote "R" button to cancel all remote control programs. This will erase all information contained within the remote LCD window (including time of day clock). 9. ˚C/˚F: Used to select/display temperature settings in either "Celsius" or "Fahrenheit" on the hand held remote unit only. Press the remote (˚C/˚F) button (using pencil tip) to select either the Celsius or Fahrenheit scale. NOTE: To change the temperature display on the main unit, press the (Temp/Clock) " " keypad & "Clock" keypad simultaneously to alternate between the˚C & ˚F scale. NOTE: When turning off the main unit with the remote control, there may be a delayed (off) reaction (5-15 seconds) before the unit actually stops. This is normal. LCD Window 1 4 5 3 1A 2 7 This unit is featured with a factory installed "Quick Connect" and "External Water Tank" feature. When the external tank is connected to the main unit, it will "increase" the total running time of the main unit, (air conditioner and dehumidifying mode) up-to 12 hours, inclusive of both tanks. (Depending on relative humidity conditions) During air conditioner and dehumidifying modes, condensed water accumulates in a precooler drip tray located underneath the evaporator (cooling) coil. When the water reaches a predetermined level, the water flow is channeled first into the secondary external water tank. When the water level inside the secondary tank reaches a predetermined level, the water flow will reverse (backwards) and be re-directed into the primary internal tank. When the water level inside the primary tank reaches a predetermined level, the automatic float switch mechanism (safety shut-off) is activated, causing the unit to stop automatically. The fan motor will continue to operate after the water condensing cycle has terminated. (this is normal) NOTE: The float switch mechanism is activated by the water level inside the (primary) internal tank only. If the external water tank is not connected to the main unit, water flow is automatically directed inside the internal water tank. SPECIALNOTE: (Air Conditioner & Dehumidifier Modes Only) • This unit can operate without the secondary external water tank being installed, providing the primary "internal" water tank is correctly installed. • This unit cannot operate if the secondary external water tank is installed, but the primary internal water tank is not. NOTE: • The quick connect fittings supplied with both the main unit and external water tank are "self-sealing" connections. • This means as soon as the quick connects are "disconnected", water flow between the main unit and external water tank stops immediately. Especificaciones Eléctricas 1. Todo el cableado debe estar conforme a los códigos eléctricos locales y nacionales y debe ser instalado por un electricista competente. Si desea hacer alguna pregunta con respecto a las siguientes instrucciones, comuníquese con un electricista competente. 2. Inspeccione el suministro de energía disponible y resuelva todo problema de cableado ANTES de instalar y operar esta unidad. 3. Esta unidad utiliza 9.0 amperios (capacidad nominal de la placa técnica) en el Modo de Refrigeración y 12.0 amperios (capacidad nominal de la placa técnica) en el Modo de Calefacción y se puede usar en cualquier receptáculo doméstico de 15 amperios, con conexión a tierra, para uso general, y correctamente cableado. 4. Para su seguridad y protección , esta unidad está conectada a tierra a través del enchufe del cordón de potencia cuando está enchufada a un tomacorriente apropiado. Si Ud. No está seguro de que los tomacorrientes en su hogar están conectados a tierra en forma adecuada, es importante que consulte con un electricista competente. NO USE ADAPTADORES DE ENCHUFE O CABLES DE ALARGAMIENTO REGULARES CON ESTAUNIDAD. Si es necesario usar un cable de alargamiento para conectar su acondicionador de aire use un cable de alargamiento aprobado específicamente para un acondicionador de aire (disponible en cualquier tienda de ferretería local). 5. La placa técnica del fabricante se encuentra ubicada en el tablero posterior de la unidad y contiene datos eléctricos y técnicos de otro tipo específicos de esta unidad. 6. Para evitar la posibilidad de heridas personales, siempre desconecte el suministro de corriente a la unidad antes de instalarla y/o repararla. Tabla 1 Circuito de desviación individual sugerido Amperios según la plata técnica 7.4 a 12.0 Tamaño AWG del cable * 14 AWG - Calibre Americano de Cables * Basado en cables de cobre de capacidad nominal de 60° C de temperatura. Tabla 2 Tipos de receptáculo y de fusibles Capacidad nominal de tensión 125 Amperios 15 Tomacorriente de pared Tamaño del fusible Fusible temporizado (o disyuntor) 15 Tipo enchufe Especificaciones de la unidad Capacidad de refrigeración Capacidad de calefacción (Alta/Baja) Capacidad de deshumidificación Nivel de ruido Fuente de energía Refrigerante Capacidad del tanque de agua interno Capacidad del tanque de agua externo Peso de la unidad Dimensiones de la unidad (pulgadas) ancho x profundidad x alto Dimensiones de la unidad (cm) ancho x profundidad x alto Velocidades del ventilador Tablero de control (iluminado) Control remoto Reloj de la hora del día Reloj automático Consumo de potencia: Refrigeración Calefacción Deshumidificación Ventilación NOTA: Las especificaciones están sujetas a cambios sin aviso previo, para mejoras futuras. Modelo DPAC8399 8300Btu/h 1380W/830W 57 pintas (27/24 horas) Menos de 54 dB (A) 115 V /60 Hz R22 5.5 L(11.6 Pints) 8.5 L(18 Pints) 38 kg (83.7 lbs) 15 1/4" x 18" x 32 5/8" 38.7 x 45.6 x 82.9 3 Controles sensibles al tacto Sí Sí Sí 1050 vatios (9.0 amperios) 1380 vatios (alto) 12.0 amperios 830 vatios (bajo) 7.2 amperios 1050 W (9.0 amperios) 90 W (0.8 amperios)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

Remote Control Operating
Instructions (cont’d)
6.
Swing Setting:
Press the remote
“Swing”
button to activate the automatic air swing
(oscillation) feature.
The symbol "
" will
momentarily appear in the LCD window
confirming the "swing" feature is activated and/or
deactivated.
7.
L(Lock) Button:
Press the remote
“L”
button to
guard against accidental program change.
When
the
“L”
button is depressed, the lock symbol (
)
will be displayed in the remote LCD window.
Press the
“L”
button again to unlock the
registered program (key symbol will disappear).
8.
R (Re-set) Button:
Press the remote
“R”
button
to cancel all remote control programs.
This will
erase all information contained within the remote
LCD window (including time of day clock).
9.
˚C/˚F:
Used to select/display temperature
settings in either
“Celsius”
or
“Fahrenheit”
on
the hand held remote unit only.
Press the remote
(˚C/˚F) button (using pencil tip) to select either the
Celsius or Fahrenheit scale.
NOTE:
To change the temperature display on the
main unit, press the
(Temp/Clock)
“ keypad
&
“Clock”
keypad simultaneously to alternate
between the˚C & ˚F scale.
NOTE:
When turning off the main unit with the
remote control, there may be a delayed (off)
reaction (5-15 seconds) before the unit actually
stops.
This is normal.
How the External Water Tank
Feature Works
This unit is featured with a factory installed "Quick
Connect" and "External Water Tank" feature.
When
the external tank is connected to the main unit, it will
"increase" the total running time of the main unit, (air
conditioner and dehumidifying mode) up-to 12 hours,
inclusive of both tanks.
(Depending on relative
humidity conditions)
During air conditioner and dehumidifying
modes, condensed water accumulates in a pre-
cooler drip tray located underneath the evaporator
(cooling) coil.
When the water reaches a
predetermined level, the water flow is channeled first
into the secondary external water tank.
When the
water level inside the secondary tank reaches a
predetermined level, the water flow will reverse
(backwards) and be re-directed into the primary
internal tank.
When the water level inside the
primary tank reaches a predetermined level, the
automatic float switch mechanism (safety shut-off) is
activated, causing the unit to stop automatically.
The
fan motor will continue to operate after the water
condensing cycle has terminated. (this is normal)
NOTE: The float switch mechanism is activated
by the water level inside the (primary) internal
tank only.
If the external water tank is not connected to the
main unit, water flow is automatically directed inside
the internal water tank.
SPECIALNOTE:
(Air Conditioner & Dehumidifier Modes Only)
This unit can operate without the secondary
external water tank being installed, providing the
primary "internal" water tank is correctly installed.
This unit cannot operate if the secondary external
water tank is installed, but the primary internal water
tank is not.
NOTE:
The quick connect fittings supplied with both the
main unit and external water tank are "self-sealing"
connections.
This means as soon as the quick connects are
"disconnected", water flow between the main unit
and external water tank stops immediately.
LCD Window
1
4
3
2
7
5
1A
Especificaciones Eléctricas
1.
Todo el cableado debe estar conforme a los códigos eléctricos locales y
nacionales y debe ser instalado por un electricista competente.
Si
desea hacer alguna pregunta con respecto a las siguientes
instrucciones, comuníquese con un electricista competente.
2.
Inspeccione el suministro de energía disponible y resuelva todo
problema de cableado ANTES de instalar y operar esta unidad.
3.
Esta unidad utiliza 9.0 amperios (capacidad nominal de la placa
técnica) en el
Modo de Refrigeración
y 12.0 amperios (capacidad
nominal de la placa técnica) en el
Modo de Calefacción
y se puede
usar en cualquier receptáculo doméstico de 15 amperios, con conexión
a tierra, para uso general, y correctamente cableado.
4.
Para su seguridad y protección , esta unidad está conectada a tierra a
través del enchufe del cordón de potencia cuando está enchufada a un
tomacorriente apropiado. Si Ud. No está seguro de que los
tomacorrientes en su hogar están conectados a tierra en forma
adecuada, es importante que consulte con un electricista competente.
NO USE ADAPTADORES DE ENCHUFE O CABLES DE
ALARGAMIENTO REGULARES CON ESTAUNIDAD.
Si es
necesario
usar un cable de alargamiento para conectar su acondicionador de aire
use un cable de alargamiento aprobado específicamente para un
acondicionador
de aire (disponible en cualquier tienda de ferretería
local).
5.
La placa técnica del fabricante se encuentra ubicada en el tablero
posterior de la unidad y contiene datos eléctricos y técnicos de otro tipo
específicos de esta unidad.
6.
Para evitar la posibilidad de heridas personales, siempre desconecte el
suministro de corriente a la unidad antes de instalarla y/o repararla.
Tabla 1
Circuito de desviación individual sugerido
Amperios según la plata técnica
Tamaño AWG del cable *
7.4 a 12.0
14
AWG – Calibre Americano de Cables
* Basado en cables de cobre de capacidad nominal de
60° C de temperatura.
Tabla 2
Tipos de receptáculo y de fusibles
Capacidad nominal de tensión
125
Amperios
15
Tomacorriente de pared
Tamaño del fusible
15
Fusible temporizado (o disyuntor)
Tipo enchufe
Especificaciones de la unidad
Modelo DPAC8399
Capacidad de refrigeración
8300Btu/h
Capacidad de calefacción (Alta/Baja)
1380W/830W
Capacidad de deshumidificación
57 pintas (27/24 horas)
Nivel de ruido
Menos de 54 dB (A)
Fuente de energía
115 V /60 Hz
Refrigerante
R22
Capacidad del tanque de agua interno
5.5 L(11.6 Pints)
Capacidad del tanque de agua externo
8.5 L(18 Pints)
Peso de la unidad
38 kg (83.7 lbs)
Dimensiones de la unidad (pulgadas) ancho x profundidad x alto
15
1
/
4
" x 18" x 32
5
/
8
"
Dimensiones de la unidad (cm) ancho x profundidad x alto
38.7 x 45.6 x 82.9
Velocidades del ventilador
3
Tablero de control (iluminado)
Controles sensibles al tacto
Control remoto
Reloj de la hora del día
Reloj automático
Consumo de potencia:
Refrigeración
1050 vatios (9.0 amperios)
Calefacción
1380 vatios (alto) 12.0 amperios
830 vatios (bajo) 7.2 amperios
Deshumidificación
1050 W (9.0 amperios)
Ventilación
90 W (0.8 amperios)
NOTA:
Las especificaciones están sujetas a cambios sin aviso previo, para mejoras futuras.